3-3 Output mode inverting (window comparator
mode 4 only)
The output of any channel can be inverted.
Output mode inverting
S-0
: Non-inverted (normally open)
S- 1
: Inverted (normally closed)
Handling Precautions
• This function is disabled in any mode other
than window comparator mode 4.
3-4 Switch output response time setting
It is possible to set the amount of response time that
elapses (on-delay) until the switch output of a chan-
nel turns on.
Switch output response time setting
Sb- 1
: Disabled (3 ms or less)
Sb-3
: 100 ms or less
Sb-2
: 20 ms or less
Sb-4
: 1000 ms or less
■
Operation mode
●
Window comparator mode 1
L1 and L2 can be set to desired levels. If the flow rate
is increasing, SW output is not turned ON.
●
Window comparator mode 2
L1 is automatically set according to the
∆
L setting
and reference flow value (L1 = "reference flow
value" -
∆
L). If the flow value is increasing, output
is not turned ON.
●
Window comparator mode 3
L1 is automatically set according to the
∆
L setting
and reference flow value (L1 = "reference flow
value" -
∆
L).
Handling Precautions
• Do not input a trigger signal for memorizing
reference flow value frequently in window
comparator mode 2 or 3. Doing so might
cause the number of EEPROM erase-write
cycles to exceed the guaranteed amount.
●
Window comparator mode 4
L1 and L2 can be set to desired levels.
●
Hardware requirement
PC: PC-98 series or equivalent DOS/V machine
OS: Windows 95 or later
●
Software requirement
HyperTerminal, a standard accessory of Windows 95
or later, is used. For details about how to set up
HyperTerminal, Page
8.
●
Communications parameters
Item
Contents
Transmission speed
9600bps
Stop bits
1bit
Parity
Odd
Parity check
Yes
Data bit length
8 bits
Communications method
Full duplex
Return key send procedure
CR/LF codes
SW output
L1
L2
ON
t
Flow rate
(L/min)
Hysteresis
Hysteresis
Open
Vacuum ON
Break
Hold
L2
L1
∆
L
ON
t
SW output
Flow rate
(L/min)
Hysteresis
Open
Vacuum ON
Break
Hold
Hysteresis
Trigger signal
for memorizing
reference flow value
L2
L1
∆
L
ON
t
SW output
Flow rate
(L/min)
Hysteresis
Open
Vacuum ON
Break
Hold
Trigger signal
for memorizing
reference flow value
L1
L2
ON
t
SW output
Flow rate
(L/min)
Hysteresis
Hysteresis
Open
Vacuum ON
Break
Hold
(At same time)
Steps
Key operation
7-seg. LED
Remarks
selects channel
or
ch-
1
SEf
1
SEf2
SEf3
SEf
1
2
3
4
5
6
The switch output response time
setting is activated
7
or
select the switch output
response time setting using
Sd-
1
selects channel
sets mode
Output mode is inverted
(At same time)
or
or
CH
1
S-0
SEf
1
SEf2
SEf3
SEf
1
2
3
4
5
Steps
Key operation
7-seg. LED
Remarks
5
RS-232C Communications