AB-7050 

Part Numbers of Optional Items 

Mount Neosensor with the following optional items (sold separately).  Order necessary items. 

Item 

Part number/Model number 

Wall-direct mounting kit 

Part No. 83165803-001 

Thermoplate mounting kit 

Part No. 83165803-011 

Dedicated mounting kit 

Multi-Thermocase mounting kit  Part No. 83165803-021 
Thermoplate for individual room 
control 

Models QY1100C and QY1100D  
(with rotary switch) 
Part No. DY2000A1022 

For mounting one Neosensor, lengthwise 

Part No. DY2000A1023 

For mounting one Neosensor, crosswise 

Part No. DY2000A2023 

For mounting two Neosensor in 94mm (H) x 192mm (W) 
outlet box, crosswise 

Part No. DY2000A2024 

For mounting two Neosensor in 106mm (H) x 198mm 
(W) outlet box, crosswise 

Thermoplate 

Part No. DY2000A3022 

For mounting three Neosensor, crosswise 

Part No. DY2000A1021 

For mounting one Neosensor, square 

Part No. DY2000A2021 

For mounting two Neosensor, crosswise 

Thermoplate for open wiring 
* Thermoplate for open wiring 

is used for open wiring 
installation. 

Part No. DY2000A3021 

For mounting three Neosensor, crosswise 

Auxiliary device 

Multi-Thermocase Model 

TY1100Z 

LAN cable 

Part No. DY7210 

 

For modular connection type Neosensor 
* Use Part No. DY7210 or the cable that meets the 

following: 
TIA/EIA-568 Category 3 or over (

⌀0.5 x 4 pairs) 

* For the wiring length, refer to the 

Specifications/Instructions document of the controller 

in connection with Neosensor.

 

TIA/EIA: Telecommunications Industry Association/Electronic Industries Association 

 

Dedicated mounting kits for each mounting method 

Mounting method 

Mounting kit 

Contents 

Mounting directly on a 
wall 

Mounting onto 
Thermoplate for open 
wiring 

Wall-direct mounting kit 
(Part No. 83165803-001) 

 

Mounting onto 
Thermoplate 

Thermoplate mounting kit 
(Part No. 83165803-011) 

 

Mounting in 
Multi-Thermocase 

Multi-Thermocase mounting kit 
(Part No. 83165803-021) 

 

 

One flat-head machine 
screw  (M3 

×

 16) 

Main unit

Mounting plate

Two pan-head machine screw (M4 

×

 8)

Man unit 

Two tapping screws (M2.6 

×

 8)

Main unit 

66.7 mm 

Mounting screws are supplied with 
the Multi-Thermocase (optional).

Summary of Contents for HTY7043T1P00

Page 1: ...sing Neosensor is thus suitable for various applications such as commercial building air conditioning or other indoor uses Note The specification data of the two wire 4 20mA output model of Neosensor...

Page 2: ...bligatory action to prevent possible danger The symbol inside graphically indicates the actual action to be carried out For example the sign on the left indicates general instructions CAUTION Use the...

Page 3: ...ow Available model numbers Model number Type Power Humidity output Temperature output Signal output wire connection Company logo HTY7043T1P00 Yes HTY7043T1P00 1 Neosensor 24 V DC AC 1 5 VDC RTD Pt100...

Page 4: ...iring Thermoplate for open wiring is used for open wiring installation Part No DY2000A3021 For mounting three Neosensor crosswise Auxiliary device Multi Thermocase Model TY1100Z LAN cable Part No DY72...

Page 5: ...tion resistance Min 500 V DC 20 M Withstand voltage 500 V AC applied for 1 min with max of 1 mA leakage current between housing and terminals Environmental conditions Rated operating condition Limit o...

Page 6: ...tead of lead wires Model TY7043Z0P01 1 Figure 1 Mounting dimensions mm Neosensor with Wall direct mounting kit Neosensor high sensitive type Note For wiring secure more than 15 mm clearance inside the...

Page 7: ...unting surface when installing Neosensor with Thermoplate mounting kit 2 The number of lead wires differs depending on the models Note that the Pt100 temperature sensor model with modular connection h...

Page 8: ...th Thermoplate mounting kit Figure 5 Mounting dimensions mm Neosensor high sensitive type with Thermoplate mounting kit on Thermoplate Thermoplate mounting kit Figure 6 Dimensions mm Mounting plate of...

Page 9: ...sensor model with modular connection has a modular jack instead of lead wires Model TY7043Z0P01 1 Figure 7 Mounting dimensions mm Neosensor not covered with Multi Thermocase mounting kit Multi Thermoc...

Page 10: ...rated by office device or equipment for example stays on Air circulation is interfered by furniture or door for example Temperature and or humidity sensing is affected by draft downdraft and hot cold...

Page 11: ...14 5 Set the depth change levers on the bilateral sides of the Neosensor main unit to the upper position indicated with L shown in Fig 17 6 Mount the main unit of Neosensor on the main unit of the Wa...

Page 12: ...d with L shown in Fig 17 6 Mount the main unit of Neosensor on the main unit of the Wall direct mounting kit with four mounting screws M3 16 supplied with Neosensor 7 Attach the cover back to the Neos...

Page 13: ...on the bilateral sides of the Neosensor main unit to the upper position indicated with L shown in Fig 17 7 Mount the main unit of Neosensor on the main unit of the Thermoplate mounting kit with four...

Page 14: ...lled with its cover removed IMPORTANT Before installing Neosensor in the Multi Thermocase be sure to set the depth change levers on the bilateral sides of the Neosensor main unit at the lower position...

Page 15: ...pth change Raising the Neosensor main unit 3 Set the depth change levers located on the bilateral sides on the main unit front surface at the lower position The levers are factory set at the upper pos...

Page 16: ...ck Blue Black 24 V AC DC 1 5 V DC 0 10 V DC Power supply Humidity Models HY7043T1000 1 and HY7043T6000 1 Figure 22 Terminal wiring Humidity sensor with 1 5V 0 10V humidity output 24 V AC DC power Pt10...

Page 17: ...sor temperature humidity sensor models IMPORTANT Use isolated transformer to supply 24 V AC power Single Neosensor must be powered by a single 24 V AC transformer If the multiple Neosensor or a Neosen...

Page 18: ...wing Use a controller with low pass filter 40 dB or higher removal ratio in normal mode that receives signals from Neosensor For insufficient removal ratio provide an isolator on the controller input...

Page 19: ...ration Neosensor is factory calibrated and does not require field calibration right after installation However field calibrate Neosensor if a shift in the output due to aged deterioration is found For...

Page 20: ...ademark of Azbil Corporation in Japan or in other countries Specifications are subject to change without notice Building Systems Company http www azbil com Rev 2 0 Sep 2015 AB 7050 J AI 7050 Rev 3 2 P...