Indicators

Figure 7. Indicator positions

Item

Product indicator

Color

State

Description

Power indicator

POWER

Green

Lit

Power ON

Flashing Power ON

(Lithium ion capacitor module being 
charged)

Not lit

Power OFF

System error indicator

ERROR

Red

Lit

Abnormal

Note: Contact Azbil Corporation.

Flashing

Not lit

Normal

Active indicator for redundant 

product configuration

ACT

Green

Lit

The device is operating (active).

Not lit

The device is for backup (standby).

Storage access indicator

STORAGE

Green

Lit

The data storage is being accessed.

Not lit

The data storage is not being accessed.

ETHERNET communication 
indicator

LAN1 100
LAN2 100 (not used)

Green

Lit

A link is established at 100 Mbps.

Flashing Data is being received or transmitted at 

100 Mbps.

Not lit

A link has not been established.

LAN1 1000
LAN2 1000 
(not used)

Green

Lit

A link is established at 1000 Mbps.

Flashing Data is being received or transmitted at 

1000 Mbps.

Not lit

A link has not been established.

System indicator

Indication using 
7-segment LED

Blue

Normal

The four 7-segment LEDs are lit in 
sequence at their outer edges at an 
interval of two seconds.

Abnormal Indication other than above.

DI status indicator

DI ch1–ch8

Green

Lit

DI status is ON.

Not lit

DI status is OFF.

DO status indicator

DO ch1 and ch2

Green

Lit

DO status is ON.

Not lit

DO status is OFF.

Indicator (not used)

IN

OUT

LAN1 100 1000

DI1  DI2  DI3  DI4

POWER

DI5  DI6  DI7  DI8

D01 D02

ERROR

ACT

STORAGE

7-segment LED

LAN2 100 1000 (not used)

REDUNDANT IN OUT (not used)

Summary of Contents for BH-101G0N0000

Page 1: ...the following applications is available as required Equipment status monitoring This product monitors up to 5000 points of the data below It is possible to connect up to 30 Supervisory Controllers to...

Page 2: ...t failure ratio and least deterioration over time is estimated scientifically based on acceleration tests endurance tests etc taking into consideration the operating environment conditions and frequen...

Page 3: ...g may cause fire or electric shock General All wiring must comply with applicable codes and ordinances Otherwise there is a danger of fire CAUTION General Strip the insulation from cables as speci fie...

Page 4: ...te I O module Model RJ 11_ _ Model RJ 11_ _ Model WJ 1111 Remote I O network 6 Model RJ 11_ _ Model RJ 12_ _ Compact Remote I O Module Model RJ 12_ _ Switching hub 1 Switching hub Switching hub Switch...

Page 5: ...anel and Neoplate devices AB 7530 Operator Panel Panel Mount Type Operator Panel Integral Type Specifications Instructions 5 A network that connects the Advanced Controller for Chiller Units Advanced...

Page 6: ...Modified PPE silver Fan bracket Hot dipped steel plate 1 mm thick Lens Polycarbonate transparent DIN holder Polyacetal black Key top Aluminum alloy Al Mg Panel Polycarbonate board 2 mm thick transpar...

Page 7: ...alent stranded cable 1 25 2 0 mm2 Daisy chain supported only for cables with the same cross sectional area of 1 5 mm2 Ground 600 V PVC insulated cable IEC 60227 3 CVV equivalent stranded cable 1 25 2...

Page 8: ...state LEDs USB 3 0 not used DO status LED ETHERNET LAN1 ETHERNET LAN2 not used Display port not used Power switch Power supply connector User operation switch 7 segment LED Power supply connector LED...

Page 9: ...oduct must be installed in a control panel cabinet Note A unit that satisfies the following conditions is considered to be equivalent to a control panel Flame resistance V 1 or higher UL 94 standard S...

Page 10: ...der the product Air inlet 0 0174 m2 198 long oval holes measuring 3 30 mm or larger under the panel door 40 mm duct Clearance in front of the product When a device from which hot air is exhausted is i...

Page 11: ...s Model 83104567 001 After installation keep the connectors that come with the device because they will be used for wiring connection Pull out Hook Push up Direct Installation with Screws Install the...

Page 12: ...etween adjacent terminals If it is too short it may not make proper contact General Tighten the terminal screws with the spec ified torque Insufficient tightening of the terminal screws may cause fire...

Page 13: ...lock Terminal Nos 4 to 11 Terminal Nos 12 to 19 Direct input DI terminal block Terminal block not used Terminal Nos 24 to 27 Direct output DO terminal block Terminal Nos 20 to 23 1 Strip 7 mm of insul...

Page 14: ...vice alarm 23 4 DO CH2 common 24 5 Not used 25 6 Not used 26 7 Not used 27 8 Not used z Wiring for ETHERNET Figure 6 Handling Do the following before turning the power on 1 Check again that the wiring...

Page 15: ...or a full charge If a fully charged lithium ion capacitor module has been off for six months or more it will have fallen below the discharge stop voltage 6 9 V Charging the module in this state signif...

Page 16: ...Green Lit A link is established at 100 Mbps Flashing Data is being received or transmitted at 100 Mbps Not lit A link has not been established LAN1 1000 LAN2 1000 not used Green Lit A link is establis...

Page 17: ...as fallen off of the product The display is hard to read Inspection Procedure If the product generates abnormal noise the fan may have failed Clean the fan according to How to Clean How to Clean Built...

Page 18: ...ove the fan cover Pull the fan cover toward you while pressing down on the two triangles on the top of the fan cover Door Open Fan cover Pull out Pull out 3 Pull the connector out of the fan assembly...

Page 19: ...lace as the original one Connector Clock battery Clamp 70 8 45 10 2 1 35 max 25 2 max 9 5 max 16 16 6 Reconnect the wiring cable connector in its original position 7 Put the wiring cable into the clam...

Page 20: ...the panel cabinet accessible only to people with sufficient knowledge concerning electrical equipment This product complies with the following harmonised standards of the Electromagnetic Compatibilit...

Reviews: