Azbil BH-101G0N0000 Specifications & Instructions Download Page 1

1

 

Specifications/Instructions

AB-7333

Supervisory Controller

© 2017–2020 Azbil Corporation. All Rights Reserved.

„

Overview

This product (Model BH-101G0_0000) is a Supervisory 
Controller that collects information about a primary device 
(such as a controller) and provides that information to the 
Client PC in savic-net

 G5, Azbil Corporation's building 

management system.
This product receives point information from the primary 

device through periodic scan or state change notifi cations 

and accumulates and manages various kinds of control-
related data.
In addition, the software that can be downloaded from this 
product allows you to monitor its state using graphics and 
lists, set up several different kinds of controls including 
interlock controls and scheduling, view data such as 
charts as well as daily, weekly, monthly and yearly reports, 
and perform other operations from the Client PC.
This product can also provide information to a third-party 
BACnet device.

„

Features

Any combination of the following applications is available 
as required.

Equipment status monitoring 
This product monitors up to 5000 points of the data 
below. 

    

It is possible to connect up to 30 Supervisory Controllers 
to monitor up to 150,000 points.  

 

Each  Supervisory  Controller  can  also  be  confi gured 
for  redundancy.  (If  a  redundancy  confi guration  is 

implemented, up to 60 Supervisory Controllers can be 
connected.) 

Point information in the primary device

Direct inputs to ensure immediate detection of 

power supply state and fi re alarms from a building

Comprehensive control 
This product comprehensively controls the devices 
connected to the system to realize comfort, safety, and 

energy effi ciency.

Data management 
This product stores and manages the following data:

Data collected from the devices connected to this 
product

Data transmitted from the devices connected to 
this product

Data that has been processed for daily, weekly, 
monthly, and yearly reports based on the collected 
and transmitted data

Data visualization 
By using the software that comes with this product, 
you can display graphics, charts, and daily, weekly, 
monthly, and yearly reports on the screen of a Client 

PC or output them to a fi le.

Summary of Contents for BH-101G0N0000

Page 1: ...the following applications is available as required Equipment status monitoring This product monitors up to 5000 points of the data below It is possible to connect up to 30 Supervisory Controllers to...

Page 2: ...t failure ratio and least deterioration over time is estimated scientifically based on acceleration tests endurance tests etc taking into consideration the operating environment conditions and frequen...

Page 3: ...g may cause fire or electric shock General All wiring must comply with applicable codes and ordinances Otherwise there is a danger of fire CAUTION General Strip the insulation from cables as speci fie...

Page 4: ...te I O module Model RJ 11_ _ Model RJ 11_ _ Model WJ 1111 Remote I O network 6 Model RJ 11_ _ Model RJ 12_ _ Compact Remote I O Module Model RJ 12_ _ Switching hub 1 Switching hub Switching hub Switch...

Page 5: ...anel and Neoplate devices AB 7530 Operator Panel Panel Mount Type Operator Panel Integral Type Specifications Instructions 5 A network that connects the Advanced Controller for Chiller Units Advanced...

Page 6: ...Modified PPE silver Fan bracket Hot dipped steel plate 1 mm thick Lens Polycarbonate transparent DIN holder Polyacetal black Key top Aluminum alloy Al Mg Panel Polycarbonate board 2 mm thick transpar...

Page 7: ...alent stranded cable 1 25 2 0 mm2 Daisy chain supported only for cables with the same cross sectional area of 1 5 mm2 Ground 600 V PVC insulated cable IEC 60227 3 CVV equivalent stranded cable 1 25 2...

Page 8: ...state LEDs USB 3 0 not used DO status LED ETHERNET LAN1 ETHERNET LAN2 not used Display port not used Power switch Power supply connector User operation switch 7 segment LED Power supply connector LED...

Page 9: ...oduct must be installed in a control panel cabinet Note A unit that satisfies the following conditions is considered to be equivalent to a control panel Flame resistance V 1 or higher UL 94 standard S...

Page 10: ...der the product Air inlet 0 0174 m2 198 long oval holes measuring 3 30 mm or larger under the panel door 40 mm duct Clearance in front of the product When a device from which hot air is exhausted is i...

Page 11: ...s Model 83104567 001 After installation keep the connectors that come with the device because they will be used for wiring connection Pull out Hook Push up Direct Installation with Screws Install the...

Page 12: ...etween adjacent terminals If it is too short it may not make proper contact General Tighten the terminal screws with the spec ified torque Insufficient tightening of the terminal screws may cause fire...

Page 13: ...lock Terminal Nos 4 to 11 Terminal Nos 12 to 19 Direct input DI terminal block Terminal block not used Terminal Nos 24 to 27 Direct output DO terminal block Terminal Nos 20 to 23 1 Strip 7 mm of insul...

Page 14: ...vice alarm 23 4 DO CH2 common 24 5 Not used 25 6 Not used 26 7 Not used 27 8 Not used z Wiring for ETHERNET Figure 6 Handling Do the following before turning the power on 1 Check again that the wiring...

Page 15: ...or a full charge If a fully charged lithium ion capacitor module has been off for six months or more it will have fallen below the discharge stop voltage 6 9 V Charging the module in this state signif...

Page 16: ...Green Lit A link is established at 100 Mbps Flashing Data is being received or transmitted at 100 Mbps Not lit A link has not been established LAN1 1000 LAN2 1000 not used Green Lit A link is establis...

Page 17: ...as fallen off of the product The display is hard to read Inspection Procedure If the product generates abnormal noise the fan may have failed Clean the fan according to How to Clean How to Clean Built...

Page 18: ...ove the fan cover Pull the fan cover toward you while pressing down on the two triangles on the top of the fan cover Door Open Fan cover Pull out Pull out 3 Pull the connector out of the fan assembly...

Page 19: ...lace as the original one Connector Clock battery Clamp 70 8 45 10 2 1 35 max 25 2 max 9 5 max 16 16 6 Reconnect the wiring cable connector in its original position 7 Put the wiring cable into the clam...

Page 20: ...the panel cabinet accessible only to people with sufficient knowledge concerning electrical equipment This product complies with the following harmonised standards of the Electromagnetic Compatibilit...

Reviews: