10
AXOR Industries
Service Manual
Magnum400
TM
ver.2 rel.05/'15
1.3 Technical Data
nominal data
nominal voltage
Vac
Three phase
: 3x10% max, 3x400Vac -10%, 50/60Hz
(Single phase permetted for setup only)
min/max dc bus
voltage
Vdc
400vac
480vac
400Vdc min ÷ 800Vdc max
500Vdc min ÷ 870Vdc max
auxiliary power
supply
(for back up)
Vdc
+24Vdc (0%, +15%) - 1Adc (3Adc with brake)
Size
1,5/3
3,5/7
7/14
10/20
14/28
20/40
nominal current
Arms
1,5
3,5
7
10
14
20
peak current for
5 sec.
Arms
3
7
14
20
28
40
dissipation at
nominal current
W
30
42
56
88
165
195
dissipation with
output stage
disabled
W
20
pwm output
frequency
kHz
8
control signals
optoisolated digital inputs
+24Vdc - 7mA (PLC compatible)
optoisolated digital outputs
+24Vdc - 50mA (PLC compatible)
analog programmable outputs
±10V (±5%)
a common mode analog input (Tprc)
±10V max, 10kOhm input resistance
a differential or common analog input
(+/-vref)
±10V max, 40kOhm input resistance
pulse/dir digital inputs
+5V, optoisolated, max. frequency 250kHz
emulated encoder outputs
V
OH
=2.5V min - I
OH
=-20mA
V
OL
=0.5V max - I
OL
=20mA
Braking resistance
internal resistance
200W - 66Ohm size: 1.5/3, 3.5/7, 7/14
200W - 33Ohm size: 10/20, 14/28, 20/40.
external resistance
500W - 66Ohm size: 1.5/3, 3.5/7, 7/14.
500W - 33Ohm size: 10/20, 14/28, 20/40.
1000W - 33Ohm +33Ohm 500W size: 1.5/3, 3.5/7, 7/14.
1000W - 66Ohm // 66Ohm 500W size: 10/20, 14/28, 20/40.
set point values
400vac
480vac
695Vdc min ÷ 735Vdc max
815Vdc min ÷ 845Vdc max