6. Maintenance
Power off the machine before cleaning. Do not clean, repair or maintain the machine until
all moving parts have stopped to avoid serious injuries.
Disconnect the air supply before cleaning, repair or maintenance.
6.1 Cleaning Dust Bin
(Fig. 14)
The dust bin must be cleaned when the dust bin is 2/3 full for non-metal material. The dust bin
should be cleaned when the dust bin is half full for metal material.
In actual usage, dust bin cleaning schedules can be set after using the unit for one week.
Clean the sealing strips with a cloth when cleaning the dust bin.
6.2 Clean Dust Box
(Fig. 15)
Observe the dust box daily. The dust box must be cleaned when the dust box is 2/3 full for
non-metal material. The dust box should be cleaned when the dust box is half full for metal
material.
In actual usage, dust bin cleaning schedules can be set after using for one week. Basically, once
the machine has been used for a while in a particular operation, the user can determine a regular
schedule based on time or pieces processed for a bag emptying schedule.
6.3 Cleaning or Changing the Filters
(Fig. 16)
When the pressure drop alarm sounds, the filter needs to be cleaned. Follow the instructions
below:
1. See chapter 5.1.3 to clean the filter. Using the delayed dust cleaning every day when finishing
your job is the most efficient way to maintain the filter.
2. As shown in Fig. 16, turn the locking knob and pull out the filter. Use compressed air to clean
the dust on the outside of the filter.
3. If method 1 and 2 cannot solve the pressure drop problem, this means the filter is failing and
must be changed.
Filter changing instruction
As shown in Fig. 16, turn the filter locking knob and
pull out the filter.
Unscrew the 6-M6x16 screws, take out the old filter
and then put the new filter in.
As shown in Fig. 16, mount the new filter, screw the
6- M6x16 screws back into place and turn and firmly
lock the knob.
Fig. 16
The same filter must be used as provided by the manufacturer.
The filter lifetime is approximately 1000-3000 hours depending on the conditions of the
working environment including but not limited to: the amount of usage, type of dust
material, type of dust density and the diameter of the particles. Dust collection results may
vary. Filter changing will vary according to the actual dust collection activities and/or filter
cleaning result.