5.1.3 Parameter and Mode Setting
1. Start/Stop Mode Interface
There are two start/stop modes of the machine.
The operation steps are as followings:
(1) Switch to the Start/Stop Mode Interface by pressing
, as shown in
Fig. 10-2
.
Manual start/stop mode.
Intelligent linkage start/stop mode. In this mode, the dust source equipment should be
connected to the Synchronous Control. (See
5.3 Operation Instructions of the
Synchronous Control
).
(2) Press
, move the cursor “>”to the desired mode.
(3) Press
, the asterisk
“
*
”
will display in front of the desired mode indicating that the setting
is working now.
Fig.10-2
2. Running Mode Interface
The machine can run in Speed Adjustment mode or Flow Cruise mode. While in Speed
Adjustment mode, the speed can be adjusted by the
Knob D
(
Fig. 9
); while in Flow Cruise mode,
the power set by the user will not change.
The operation steps are as followings:
(1) Switch to the Running Mode Interface by pressing
, as shown in
Fig. 10-3
.
Speed
:
Speed Adjustment mode
1760W
:
1200W Constant Power mode
1980W
:
1350W Constant Power mode
2200W
:
1500W Constant Power mode
2420W
:
1575W Constant Power mode
(2) Press
, move the cursor “>”to the desired parameter or mode.
(3) Press
, the asterisk
“
*
”
will display in front of the desired parameter or mode indicating
that the setting is working now.
Note
: After you complete the conversion of running mode, the new running mode will not work
until you reconnect the power.