TECHNICAL SPECIFICATIONS
MODEL NAME
AX-SPG
AX-DPG
APPLIED STANDARD
ANSI Z83.11a-2004,
CSA 1.8a-2004;
Addenda A:2004,
Issue 2002/07/01
ANSI Z83.11a-2004,
CSA 1.8a-2004;
Addenda A:2004,
Issue 2002/07/01
Qn (HEAT INPUT H
i
)
(
Btu/h)
61416
122832
BURNERS
2
4
CONSUMPTION
Natural gas:1,615 m³/h
Propane:1,482 kg/h
Natural gas:3,23 m³/h
Propane:2,96 kg/h
GAS CONNECTION
1/2” ISO 7-1:1982
3/4” ISO 7-1:1982
GAS PRESSURE
Natural gas 7” WC
Propane gas 11” WC
Natural gas 7” WC
Propane gas 11” WC
4/19
GAS PRESSURE
Natural gas 7” WC
Propane gas 11” WC
Natural gas 7” WC
Propane gas 11” WC
BURNER NOZZLES
DIAMETER
Natural gas: Ø 2,25 mm
Propane gas: Ø 1,45
mm
Natural gas: Ø 2,25 mm
Propane gas: Ø 1,45 mm
PILOT NOZZLE ( only for oven)
Ø 0.35 mm
Ø 0,35 mm
PRIMARY AIR DISTANCE (X)
(fixed by the manufacturer see
fig.6)
Open
Open
TYPE OF FLUE
Not designed for
compulsory connection
to any extraction system
Not designed for
compulsory connection to
any extraction system
AIR REQUIREMENT FOR
COMVENTILATION
(at least 2 m³/kW in one hour)
min. 30 m³/h
min. 60 m³/h
The data plate is located behind of front panel and back side of appliance.