USER MANUAL
25
____________________________________________________________________________________________________________________
15.5
Interface parameters setting
The function allows setting independently
communication parameters of both of serial ports
Port-1
and
Port-2
(executed in RS232C, RS485,
USB or LAN standard):
-
transfer protocol
(Prot):
LonG
–
cooperation with printer or computer
,
EPL
–
cooperation with label printer in normal
mode (activates
LAbEL
function),
EPL_A
–
cooperation with label printer in
automatic mode (activates
LAbEL
function),
EPL_d –
cooperation with special label printers,
Pen-01 –
cooperation with PEN-01,
-
baud rate
(bAud):
(
4800, 9600, ….115 200bps
),
-
number of bits in single char.
(bitS): 7, 8
,
-
parity control
(PArItY):
nonE
–
no control
Odd
–
nonparity
Even
–
parity control,
-
scale number in network
(nr):
(if the scale doesn’t work in network the number
must be 0)
,
-
transmission through serial interface
(SendInG)
:
StAb
–
transmission after
key is used and
result is stable,
noStAb
–
transmission after
key is pressed
without need of stabilisation,
Auto -
automatic transmission after load is put on
and result is stable
(Auto)
,
Cont -
continuous transmission, about 10 results
per second (
Cont.),
Remove
- trans
Default parameter values:
Long, 9600 bps, 8 bits, none,
StAb,
-
SCAnn –
cooperation with MJ-4209 barcode
readers.
In order to set needed parameters choose
Interface
function, select appropriate parameter and press
T
key when required option or parameter value is displayed.
In scales with an additional serial port
Port-1
and
Port-2
appears for the independent setting of both ports.
SETUP
1. Menu
2. Calibration
3. Auto-zeroing
4. Unit
5. Interface
6. Print setup
7. LCD settings
8. Language
9. Time&date
10. Keyboard
11. Analog output
12. Firmware update
13. Defaults
14. Exit
INTERFACE
1. Port 1
2. Port 2