![Axis Industries QALCOSONIC HEAT 2 Technical Description, Installation And User Instructions Download Page 36](http://html.mh-extra.com/html/axis-industries/qalcosonic-heat-2/qalcosonic-heat-2_technical-description-installation-and-user-instructions_3039900036.webp)
PESHEAT2V01
2016-01-08
36
Holding down button
stores the selection, and report ending date selection mode will be
activated. LCD displays (h mm.dd ) :
Report ending date and time is defined in the same way as describe above.
Printing will start after holding down button
one more time. While report is being printed,
blinking label “Print” will be displayed. Printing can be paused and started again (for example, to add
paper) by shortly pressing button
. If printing is paused, label “Print” will stop blinking.
To move to another menu level press and hold button
.
Press and hold button
to stop printing in any time.
8.2.6. Displaying configuration settings and programming relay output parameters (5 lygis)
Displaying configuration settings
Sequence of displayed parameters may vary depending on selected measurement scheme and
number of active sensors.
Settings also are shown, how is indicated in the Table 7.1, only are not shown an inscription the
SET. Foe example:
Serial number
Parameter values are displayed in sequence, shortly pressing buttons:
- next parameter,
-
previous parameter
Use configuration data viewing mode
“INF”
to view device configuration settings (programmed
parameters and operation modes) and – if regulation function is activated – to change relay output
parameter values.
8.3. Programming relay output parameters in regulation mode
8.3.1. Configaration parameters with codes “23:” ..”29:” (Table 7.1) are dedicated for
programming relay output parameters. When information data inspection mode
“INF
” is entered, it is
possible to activate or deactivate regulation function, also to choose regulated parameter and control relay
output manually by shortly pressing buttons
or
and selecting the parameter “23:”.
When button
is pressed for long time, regulation status symbol “On” or “Off” starts blinking.
Shortly pressing button
will activate “On1” , “On2”, or deactivate “Off” regulation function.
When the operation mode On1 is entered, shortly pressing button
will activate regulated parameter
selection mode (parameter will start blinking). Select regulated parameter code (see Table 7.1) by shortly
pressing button
.
If regulation mode is deactivated (“Off”), it is possible to control the regulated valve manually.
Shortly press button
- symbol “R” starts blinking. Pressing button
will start closing the valve –
symbol “vR” will be displayed. Pressing button
one more time will start opening the valve – symbol
“^R” will be displayed. Pressing button
once again will switch off valve control – only symbol “R”
will be displayed.