PESHEAT2V01
2016-01-08
28
Press and hold (
3 s) button
or button
to move to the next display level.
To view data in the same display level press shortly (
3 s) buttons
or
. The display will
switch automatically to the highest level of displaying current values of integral parameters, or – if at
least one error has been detected – error code will be displayed after 5 minutes of inactivity.
Fig. 8.2.
Selecting the display level
Arbitrary symbols, used in the diagrams:
At Service level it is provided two service modes:
6th level. Parameterization(configuration) mode
(SET)
SET
▼ ▼ ▼ ▼ ▼
INT PAR LOG PRN INF
7
th
level. Test mode (TEST)
TEST
▼ ▼ ▼ ▼ ▼
INT PAR LOG PRN INF
To enter the parameterization (configuration) mode (6
th
level), open the lid and press “SET”
button. Label “SET” is displayed in the upper right side of the display.
In this mode by means of control buttons or via optical interface, the use of personal computer
with special software, you can change the configuration of the meter (see section 7.2).
By short pressing “SET” button you can leave the parameterization mode and enter to test mode
(7
th
level).
Press the “SET” button once to leave the test mode and confirm return to the 1
st
level.
On Each level the list of displayed parameters may be reduced and the parameter listing order can be
changed (on SET mode, using the computer with the special software, joining via the optical or wire
communication interface) depending on the user requirements.
8.2.2. Displaying integral parameter values (level 1)
Accumulated total energy ( ∑E )
Accumulated Energy component (E1)
Accumulated Energy component (E2)
PAR
LOG
PRN
INF
INT
- left button,
- right button, - long press (
3 s) - short press(
3 s)