UMAX090690. Version: 1.2 Preliminary Documentation
– May Be Subject To Change
23-37
Name
Range
Default Value
Control Source
0…3
0 (Disabled)
Control Number
0…10
(Only applies to CAN rx)
Maximum Inductor Temperature
0…100.0
100 Deg C
Inductor Temperature Hysteresis
0.0…Max
90 Deg C
Precharge Mode Start Voltage
2.5…10.6
9.0 Volts
Precharge Mode Regulation Current
0.0…1.2
0.5 Amps
Constant Current Mode Start Voltage
4.5
…12.6
10.6 Volts
Constant Current Mode Regulation Current
0.5…1.2
1.2 Amps
Constant Voltage Mode Start Voltage
10.6
…12.6 12.6 Volts
Constant Voltage Charge Mode Stop Current
0.0…1.2A 0.3 Amps
Constant Voltage Mode Regulation Voltage
10.6
…12.6 12.6 Volts
Charge Termination Mode Regulation
Current
0.0…0.3
0.0 Amps
Recharge Mode Start Voltage
10.6…12.6 12.3 Volts
Recharge Mode Regulation Current
0.3…1.2
1.2 Amps
Precharge Mode Force Enable
0…1
0 (Disabled)
RTD Enable
0…1
0 (Disabled)
Table 7
– Default Charging Profile Setpoints