User Manual UMAX090690. Version: 1.2 34-37
8. INSTALLATION INSTRUCTIONS
Electrical Connections
Integral TE Deutsch 12 pin receptacle (P/N: DTM04-012PA)
18 AWG wire is recommended for use with contacts 0462-201-16141.
PIN #
FUNCTION
1
V IN-
2
BATT 1 -
3
BATT 2 -
4
BATT 1 RTD -
5
BATT 2 RTD -
6
CAN L
7
CAN H
8
BATT 2 RTD +
9
BATT 1 RTD +
10
BATT 2 +
11
BATT 1 +
12
V IN+
Mating Connectors
PL-DTM06-12SA Mating Plug Kit is comprised of 1 DTM06-12SA, 1 WM-12S
wedge, 10 0462-201-20141 contacts, and 2 0413-204-2005 Sealing
Plugs.
Mounting
Mounting holes are sized for #8 or M4 bolts. The bolt length will be
determined by the end-
user’s mounting plate thickness. The mounting
flange of the controller is 0.425 inches (10.8 mm) thick. It should be
mounted with connectors facing left or right to reduce likelihood of
moisture entry. All field wiring should be suitable for the operating
temperature range. Install the unit with appropriate space available for
servicing and for adequate wire harness access (6 inches or 15 cm)
and strain relief (12 inches or 30 cm).