19
4)
Select the default sampling rate or you can select other desired sampling rate.
5)
Now press the Start in the PC-LINK SOFT to measure and view the synchronic data or graph in the
software interface.
6)
To disable the serial data output function, press SHIFT and then press RANGE again.
7)
More information about the PC-LINK SOFT, please refer to the Help topic including in the
software or enter our webside: www.mastech.com.cn
4.
TECHNICAL SPECIFICATIONS
4.1.
General specifications
Environment conditions:
1000V CAT III and 600V CAT IV
Pollution degree:
2
Altitiude:
<2000m
Operating temperature:
0
~
40
°
C, 32
°
F
~
122
°
F(<80%RH, <10
°
C non-condensing)
Storage temperature:
-10
~
60
°
C, 14
°
F
~
140
°
F(<70%RH, battery removed)
Temperature Coefficient:
0.1x(specified accuracy)/
°
C(<18
°
C or >28
°
C)
Max Voltage between terminals and earth ground: 1000V AC rms or 1000V DC.
Fuse Protection:
µ
A and mA:
F 0.63A/1000V
Ø
10.3x38;
A:F10A/1000V
Ø
10,3x38
Sample Rate:
3 times/sec for digital data
Display:
6600 counts. Automatic indication of functions and symbols.
Range selections:
automatic and manual.
Over Range indication:
LCD will display “OL”
Low battery indication:
The is displayed when the battery is under the proper
operation range.
Polarity indication:
“-“ displayed automatically
Power source:
9V
Battery type:
6F22
Dimensions:
190(L)x90(W)x40(H)mm
Weight:
500g.approx.(battery included)
4.2.
Measurement specifications
Accuracy is specified for one year after calibration, at operating temperatures of 18
°
C to 28
°
C,
with relative humidity at 0% to 75%.
Accuracy specifications take the form of:
±
(% of Number of Least Significant Digits)
4.2.1.
AC Voltage
ACV:
Range
Resolution
Accuracy
60Hz
40Hz~400Hz