20
660mV
0.1mV
±(1.0% +5)
6.6V
1mV
±(1.0% +5)
66V
10mV
±(1.0% +5)
660V
100mV
±(1.0% +5)
1000V
1V
±(1.5% +5)
Above accuracies can be guaranteed within 5%
~
100% of the full range.
The true RMS meter and the true RMS+PEAK meter has residual value within 10 counts when the test
leads are shorten, but that will not affect the accuracy of measurement.
4.2.2.
DC Voltage
DCV:
Range
Resolution
Accuracy
660mV
0.1mV
±(0.5% +5)
6.6V
1mV
±(0.8% +5)
66V
10mV
±(0.8% +5)
660V
100mV
±(0.8% +5)
1000V
1V
±(1.0% +2)
4.2.3.
Frequency
Logic frequency (1Hz-1MHz)
Function
Range
ResolutionaCCURACY
Dokładność
Frequency
(6Hz-66MHz)
66.00Hz
0.01Hz
±(0.1%+3)
660.0Hz
0.1Hz
6.600kHz
0.001kHz
66.00kHz
0.01kHz
660.0kHz
0.1kHz
6.600MHz
1KHz
66.00MHz
10KHz
Linear frequency (6HZ
~
10KHZ)
Function
Range
Resolution
Accuracy
Frequency
(6Hz-66KHz)
600mV
600mV
±(0.05%+8)
6.6V
2V
66V
10V
660V
20V
Above accuracies can be guaranteed within 10 %
~
100% of the full range
4.2.4.
Duty cycle
Range
Resolution
Accuracy
1% ~ 99%
0.01%
±(2%+10)
4.2.5.
Resistance
Range
Resolution
Accuracy
660.0
Ω
0.1
Ω
±(1.2%+2)
6.600k
Ω
1
Ω
66.00k
Ω
10
Ω
660.0k
Ω
100
Ω
6.600M
Ω
1k
Ω
66.00M
Ω
10k
Ω
±(2%+5)