Simulcrypt User Guide
Conditional Access system setup starts by installing and configuring CAS server that, among others,
generates ECMs and EMMs. CAS server setup is not covered in this guide.
Simulcrypt setup at headend side is started from Maintenance → CAS Settings. Tables described in
the next chapters must be configured according to CAS server setup.
1) Global CAS settings
- Enable Simulcrypt:
Simulcrypt license needed to activate.
- Network interface
used for all simulcrypt-related network traffic. By default Ethernet-port
labeled as CAS is used. IP address of this port must be configured for EMMG (CAS server).
- EMMG Listening Port:
TCP port configured in EMMG (CAS server) to connect the headend.
2) CAS list
Add here all connected CA-Systems. Each CA-System is identified by two IDs, the “CA_system_id”
(CAS ID) and “CA_subsystem_id” (Sub ID). Sometimes both values can be seen combined to a single
“Super_CAS_id”. This table is to map CAS ids to human readable names in the next tables.