Industry

 

Partner

Summary of Contents for PV-1072

Page 1: ...RCODE EXPERTS Church Road Weston on the Green Oxfordshire OX25 3QP UK Tel 44 0 1869 351155 Email sales axicon com Web www axicon com operating manual Axicon PV 1072 portable barcode verifier Industry Partner ...

Page 2: ...Page 2 of 24 Axicon Auto ID Limited PV 1072 operating manual June 2017 www axicon com ...

Page 3: ...11 ISO IEC or ANSI grades 13 Menu screen formats 14 Frequently asked questions 15 Technical specifications 17 Software licence agreement 18 Axicon warranty 20 Declaration of ISO IEC 21 Annual service 22 Declaration of CE 23 Contact us 24 Page 3 of 24 Axicon Auto ID Limited PV 1072 operating manual June 2017 www axicon com ...

Page 4: ...warranty If the verifier read head is dropped or subjected to similar misuse the accuracy of the results may be affected The unit should be returned to Axicon immediately for servicing Axicon recommends that for optimum accuracy all verifier read heads should be returned every year to Axicon or an approved reseller to be factory recalibrated Any attempt to dismantle the equipment or any Axicon ver...

Page 5: ...t containing the operating manual and the calibration card Belt bag to enable the unit to be carried easily around a factory or warehouse Not supplied as standard in the U S A set of four AA sized alkaline batteries supplied in Europe only www axicon com Page 5 of 24 Axicon Auto ID Limited PV 1072 operating manual June 2017 ...

Page 6: ...conds This is the power up and initialisation phase The PV 1072 will show an initialising message before showing the message Axicon Verifier Ready to Scan If the PV 1072 is left for some time the screen will go blank to conserve battery power but can quickly be restarted by pressing the on off button again The time out period before this happens can be adjusted to suit the requirements of the user...

Page 7: ...d the value for RMax Press Menu Select and you can change the value by using the Scroll up and Scroll down buttons until it matches the value shown on the calibration card Press Menu Select to confirm the setting Press the Scroll down button and the message will be displayed Calibrate Press the Menu Select button The message will be displayed Calibrate Cal Scan 0 3 Pick up the verifier read head p...

Page 8: ...ode at different points throughout the height of the barcode which will be averaged automatically to grade the barcode This is the process defined by ISO IEC 15416 To do this simply use the Menu Select button and you will see the message Information Use the Scroll Down button until you see the message Setup Press the Menu Select button and you will see Average No 3 Press the Menu Select button and...

Page 9: ...e message Printing and shortly afterwards the message Done Press the Clear Back button to return to the main screen Please note that this is a unidirectional signal transfer if the printer is not connected properly or not switched on then the PV 1072 is not aware of this Manual saving of verification reports Verify the barcode Press the Print button the screen will show Print Press the Scroll down...

Page 10: ...t saved scans Unplug the verifier read head from the PV 1072 and plug in a USB memory device From the main screen press the Menu Select button and you will see the message Information Press Menu Select and the screen will display Show Code Press Scroll down until the message Transfer is displayed Press Menu Select The message Transferring will be displayed followed by the message Transfer Successf...

Page 11: ...Scroll Down button and Time will be displayed Press Menu Select Use the Scroll up and Scroll Down buttons until the correct time is shown and then press Menu Select to lock the data Use the Scroll Down button and Date will be displayed Press Menu Select Use the Scroll up and Scroll Down buttons until the correct time is shown and then press Menu Select to lock the data Press Clear Back until the R...

Page 12: ...e then Power Down will occur first Note that 0 Zero minutes means that the sleep mode will be disabled Press Clear Back twice to move back to the main screen To set the Power Off option On the main screen press the Menu Select button to see the message Information Use the Scroll Down button until Setup is displayed Press Menu Select Press the Scroll Down button until the screen displays the messag...

Page 13: ...dard display On the main screen press the Menu Select button to see the message Information Use the Scroll Down button until Setup is displayed Press Menu Select Press the Scroll Down button until the screen displays the message Show ANSI is displayed Press Menu Select The screen will display Show ANSI Use the Scroll up and Scroll Down buttons until the desired display format is shown Press Menu S...

Page 14: ...code Encodation Transfer Calibrate Set Rmin Set Rmax Calibrate Setup Average No Pass grade Units Language Autosave Show ANSI Time Time zone Time Date Power Sleep Power off Printer Trailing LF www axicon com Page 14 of 24 Axicon Auto ID Limited PV 1072 operating manual June 2017 ...

Page 15: ...ed on page 12 to meet your requirements If both of these are set to 0 the PV 1072 will stay on continuously Will the P 72 read head work with the PV 1000 The P 72 read head can only be used with the PV 1072 display unit How long will a set of batteries last In tests with the PV 1072 remaining continuously on a set of 2700 mAh NiMH batteries the type supplied by Axicon as an optional extra lasts at...

Page 16: ...elect once Press Scroll down twice Press Menu Select once you will see a number on the second line of the display which is the averaging number Press Scroll down three times Press Menu Select once Use the Scroll up and scroll down buttons until the chosen language is shown on the second line of the display Press Menu Select to confirm the language Press Clear Back twice to return to the Ready to s...

Page 17: ...ls CE approval see certificates below for full specification Copyright information The Axicon software embedded in the PV 1072 together with any accompanying Axicon software is the copyright of Axicon Auto ID Ltd and is subject to the software licence described below This manual is copyright to Axicon Auto ID Ltd and may not be reproduced in whole or in part nor may it be stored in any electronic ...

Page 18: ...y licensing or control features of the software Ownership The software is owned and copyrighted by Axicon Auto ID Limited Your licence confers no title or ownership in the software and is not a sale of rights in the software Copies You may not make copies of the software for any purpose whatsoever You may not copy the software onto a bulletin board or similar publicly accessible system No disassem...

Page 19: ... equipment you must satisfy yourself that its performance is suitable for your needs Neither Axicon Auto ID Limited nor the vendor of this display unit can accept any liability for any loss or damage consequential or otherwise which may be caused by its use If the equipment or any part of it is defective in any way or in some other way does not meet your expectations the liability of Axicon Auto I...

Page 20: ...hout the original case Axicon will automatically charge an additional sum for the replacement of this packaging Axicon reserves the right to charge an inspection fee for any equipment returned under warranty for which no fault is found Please contact Axicon to obtain an RMA return to manufacturer authorisation number before returning any equipment This number must be quoted on all documentation Ax...

Page 21: ...that this equipment when used with the latest verifier software and configured appropriately has the features to meet the requirements of the United States Food and Drug Administration regulation Title 21 CFR Part 11 This verifier has been quality assurance checked today and conforms to this ISO IEC standard This declaration of conformity is valid for a year Issue date Expiry date Authorised signa...

Page 22: ... it you with the latest version of the software on CD together with a new calibration card and a new user guide that will include the new certificate of ISO IEC conformance You will then need to calibrate the verifier before you use it again The latest software can always be downloaded free of charge from our website www axicon com To arrange for your verifier to be serviced 1 Contact us on Teleph...

Page 23: ...ollowing standards Barcoding ISO IEC 15426 European Safety EN 60950 Electromagnetic Compatibility EN 55022 EN 55024 We also certify that the standard EN 60825 is not applicable to the product This equipment meets the requirements of the directives 2004 108 EC Electromagnetic Compatibility 2006 95 EC Low Voltage based on our own relevant test reports Martin Morrison Managing Director Church Road We...

Page 24: ...0 1869 351 155 Fax 44 0 1869 351 205 Email info axicon com Website www axicon com As Axicon continually improves its products their specifications and features are subject to change without notice All trademarks are acknowledged as belonging to their respective companies Your Axicon distributor ...