208
MENU |ASCII COMMANDS
FALCON · User Manual · ENG
Start Content Type1:
Starting position of content type 1
Length Content Type1:
Number of characters following the first defining the content type 1
RTContent Type2:
Content type 2
Start Content Type2:
Starting position of content type 2
Length Content Type2:
Number of characters following the first defining the content type 2
Example:
The following string RT is sent:
With UECP addressing: Site Address = 2, Encoder Address = 18
RTPLUS, 1, 1, 1, 8, 7, 4, 18, 3, 2, 18
↲
Note: For more information on RT+ consult the official RDS Forum document.
Dataset
Select the active Dataset.
Keyword:
DATASET
Parameters:
DataSet number (1 to 6), [ SiteAddress, EncoderAddress ]
Answer:
DS OK
Example for Dataset 1:
DATASET, 1
↲
With UECP addressing:
DATASET, 1, 2,18
↲