137
MENU | RDS/RBDS (NOT IN FALCON D7)
FALCON · User Manual · ENG
SLC 3 (Language): This code allows to define language used by the broadcaster.
SLC 4 (n/a): not assigned.
SLC 5 (n/a): not assigned.
SLC 6 (Broadcaster use): Data reserved for internal management of broadcaster.
SLC 7 (EWS) Emergency Warning System: his data identify channel used for emergency or alert
transmission.
RBDS PI CALCULATOR (only if you are working on US soil)
CALL Letters: write the desired CALL Letters in this field, then click Convert. You will read the converted
hexadecimal value in PI Code (Ex).
PI Code (Hex): write the desired hexadecimal PI Code in this field. Then click Convert. You will read the
converted value in CALL Letters.
5.3.3.3
UECP MAIN AF
Main Network Editing Controls
Editing Dataset Index: decide which Main AF List (alternative frequencies) you want to edit, select the
related DSN (Dataset Number).