183
When a configuration file is obtained from an AX3000, the inactive parameters (undefined hosts,
print server unused, coloring mode disabled, etc) are commented out.
a) Header
BEGIN_AX_SETUP V1.1
#########################################################
# TCP/IP AX3000 Platine Terminal #
# #
# Ethernet address: 00:A0:34:20:27:10 #
# Firmware: FK18.BV2.1a/TCP.FR.1236b.STD #
# 12354 #
#########################################################
#
RESET_CMOS
Note:
the
RESET_CMOS
command allows all the set-up parameters (except the AX3000 IP
address) to be reset. This line can be deleted or set as a comment.
b) Substitution Commands
axname_encoding_string=
(yes | no)
Enabling "axname_encoding_string" allows some set-up parameters to contain 'substitution
commands'. This allows variables such as the thin client name and the session number. The
substitution is done when a set-up file is sent to the thin client.
☺
: this function is useful when multiple thin clients are configured with the same set-up file, but
each thin client requires certain unique parameters.
Notes:
- It works only through the remote set-up function. (It's not available with the interactive set-
up).
- Some set-up parameters are not supported by this function: the thin client name, the
passwords, the pre and post-printing sequences and the transparent mode sequences.
The substitution commands are:
- <$> is the parameter "tcp_axname"
- <#> is the session number (1 to 6) or the port number (AUX1=1, AUX2=2, PARALLEL=3,
NET1=4, NET2=5, NET3=6, NET4=7, USB1=8, USB2=9, USB3=10, USB4=11).
- <$(X,Y)> is an "tcp_axname" sub-string (start X, length Y).
Notes:
- If X is greater than the "tcp_axname" length, the substring is empty.
- If X+Y is greater than the "tcp_axname" length the substring is truncated.
- In event of syntax error the substitution is not done.
Example
: if the thin client name is "axel201234":
TERM<$(7,4)>
=> TERM1234
TERM<$(7,10)>
=> TERM1234
TERM<$(20,7)>
=> TERM
TERM<$(20,A)>
=> TERM<$(20,A)>
<$(1,2)><$(7,4)>-<#>
=> ax1234-2 (ex.: session 2 or AUX2)
Summary of Contents for AX3000 80
Page 1: ...AXEL Thin Client AX3000 Models 80 and 85 USER S MANUAL August 2017 Ref AX3 M8X E 1626 4...
Page 11: ...Introduction AX3000 Models 80 and 85 User s Manual 1 INTRODUCTION...
Page 14: ......
Page 19: ...Initial Power On AX3000 Models 80 and 85 User s Manual 9 2 INITIAL POWER ON...
Page 33: ...Interactive Set Up AX3000 Models 80 and 85 User s Manual 23 3 INTERACTIVE SET UP...
Page 78: ......
Page 79: ...Using the Thin Client AX3000 Models 80 and 85 User s Manual 69 4 USING THE THIN CLIENT...
Page 93: ...Installing under Windows AX3000 Models 80 and 85 User s Manual 83 5 INSTALLING UNDER WINDOWS...
Page 127: ...Installing under OS 400 AX3000 Models 80 and 85 User s Manual 117 6 INSTALLING UNDER OS 400...
Page 145: ...Installing under OS 390 AX3000 Models 80 and 85 User s Manual 135 7 INSTALLING UNDER OS 390...
Page 158: ......
Page 179: ...Tools and Statistics AX3000 Models 80 and 85 User s Manual 169 9 TOOLS AND STATISTICS...
Page 189: ...Remote Administration AX3000 Models 80 and 85 User s Manual 179 10 REMOTE ADMINISTRATION...
Page 195: ...Appendix AX3000 Models 80 and 85 User s Manual 185 APPENDIX...
Page 223: ...PERSONAL NOTES...