Set/ Reset function
1. Push the menu button for 3 seconds
2. Set/Reset function is selected with blinking text as indicated by
pushing the menu button for
seconds in sequence, as follows;
1) AWS : Water Generating function -
SET
2) U.V : U.V light self-detector function -
RESET
3) Cold water temperature - Coldest ( 7~12 ) -
SET
4) Cold water temperature - Colder ( 15~20 ) -
SET
5) Cold water temperature - Normal ( 20~25 ) -
SET
6) Air filter replacement function -
RESET
7) Water filters replacement function -
RESET
8) U.F replacement function -
RESET
9) Hybrid connection function -
SET
3. When function is selected (text blinking), push set button for
3 seconds to set/ reset the working mode.
4. To clear the Set/Reset stage, push the menu button again 3
seconds or leave it for more than 5 minutes. Then Set/Reset
function will return to previous stage.
1. To reset Air filter replacement after exchanging air filter.
1) Push menu button for 3 seconds.
2) Push menu button 5 times to go to Air filter indicator.
3) Push the Set button for more than 3 seconds.
Note: U.V/ Air filter/ Water filters/ U.V filter replacement function must be
indicator signal.
2. Setting normal cold water temperature
1) Push menu button for 3 seconds
2) Push menu button 4 times to go to Normal water temperature indicator.
3) Push the Set button for more than 3 seconds.