background image

3.PACKING LIST

Safety Instructions before starting

- Do not install and operate this appliance in a flammable and explosive environment.

- Make sure that the installation is done according to the local electricity safety regulation
of your country.
.
- Before installation and mentainence, make sure that the appliance is disconnected
from the power source.

- Do not use any power source other than 24V AC, in order to prevent damages to this
device. For details, please refer to the section "Precaution" in previous chapter for
more details.

- Handle the device during the installation carfully. Falls or extreme vibration may cause
irrepairable damages and avoid the warranty.

- Do not install or operate the appliance near any high-voltage devices or high-voltage
cable. The safety distance should remain at least 50 m.

- To archive best image quality, its recommanded to use underground cable shielded with
steel tube. Do not install the cable without any protection.

- In a thunderstorm area or region with high inductive voltage, such as high voltage
transformer stations, it is necessary to use additional lighning-proof equipments or
lightning rob for protection.

- For outdoor installation, lightning-proof and grounding of the device should be
considered. Please refer to the industrial saftey regulation and request of your country
.
- Grounding of the appliance should consider anti-interference and fulfill the saftey
requirements. Do not connect the ground with short-circuited or other high-voltage
electric network.

- The resistance of down conductor should not exceed 4 Ohm, and its thickness should
be at least 25mm²

- This appliance has the lightning-proof function which can prevent damages caused by
high-voltage pulse, such as lightning strike below 1500.

- This appliance meets the Ip66 standard for water and dust proof. Do not install the in-
door model for out-door application which is not designed with water protection. Make
sure that the installation is protected from long-time water-drop or spatter, which may
damage the appliance.

- Make sure that the enviroment of installation meets the requirement of the appliance,
such as holding the weight, enough spaces for bracket and power supply.

4.INSTALLATION

Indoor
Series

USER'S MANUAL

High Speed dome
Camera Series

Core Unit
1 Piece

Indoor Roof-Mount
base platte
1 piece

Instruction and
operation manual
1 piece

Outdoor
Series

Core Unit
1 Piece

Out-Door housing
with sun.shield and

cover

1 piece

Instruction and
operation manual
1 piece

Spare dome cover
1 piece

Outdoor
Series

Core Unit
1 Piece

Out-Door housing
with sun.shield and

cover

1 piece

Instruction and
operation manual
1 piece

Spare dome cover
1 piece

Some models may not be available in your country, please contact VIDO distributor for more details

Unpacking

The speed dome is packed with protection. please take
out the core unit carefully. In case of transportation
please use the original packing box.

WARNING:

The transparent cover part is sensitive and should

be handled with care. Do not touch or rub the surface in any way
with the protection foil.Inproper cleaning method will cause
permanent scratches on the cover and cause unclear image or
focusing error of the camera. For Cleaning the cover, please
replace the original first with the spare cover, and wash it by
diving into warm water with non-corrosive cleaning solution.

3

4

Some products may not be available in your country, please contact our distributor for more details

USER'S MANUAL

High Speed dome
Camera Series

USER'S MANUAL

High Speed dome
Camera Series

Summary of Contents for High Speed dome Camera Series

Page 1: ...USER S MANUAL v 2 66 High Speed dome Camera Series ...

Page 2: ... IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE...

Page 3: ... 140 F and a humidity below 90 The input power source is 24V AC 50 60Hz and requires 2500mA outdoor models Do not expose the indoor model of dome camera to water or moisture not try to operate it in wet areas 2 FEATURES 1 2 Some products may not be available in your country please contact our distributor for more details Some products may not be available in your country please contact our distrib...

Page 4: ...nt damages caused by high voltage pulse such as lightning strike below 1500 This appliance meets the Ip66 standard for water and dust proof Do not install the in door model for out door application which is not designed with water protection Make sure that the installation is protected from long time water drop or spatter which may damage the appliance Make sure that the enviroment of installation...

Page 5: ...hnology Depends on the cable typeand baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 4oom 4800 bps 1700m 9600 bps 19200 bps Baud Rate Max Distance Due the environmental interferences such as eletromagnetic and induction fields or number of connected appliance on the RS 485 bus the transmission...

Page 6: ...th 120 resistor on both ends Following picture illustrates the connection methods please note that a daisy chain connection type shall not exceed 7 meters Ω 120Ω Resistor Device 2 Device 3 Device 1 120Ω Resistor RS 485 RS 485 RS 485 RS 485 Termination on Termination off Termination off How to turn on termination on the high speed dome camera The termination switch is located on the rear side of th...

Page 7: ...After unpaking and during the installation the core unit should be installed as following Installing the core unit by pushing into the housing please note the position of connector For releasing please press the lever lock to core and pull off the unit Lever Lock Connector Interface Power LED Metal Clip WARNING Do not pull or hold the connector interface with force It is design only to connect the...

Page 8: ... NUMBER 1 PROGRAM PATTERN RUN PATTERN CLEAR PATTERN EDIT PATTERN LABEL BACK EXIT EDIT T O U R P0 S P0 S P0 S 00 0 00 00 0 00 00 0 00 TM TM TM B A C K E X I T 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 Z O N E S ZONES NUMBER 1 SET LEFT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL BACK EXIT DOME LABEL OFF PRESET LABEL OFF ZOOM LABEL O ZONE LAB...

Page 9: ...es the idle time prior to start a custom defined action park action The range is from 1 to 240 minutes This function can be deactivated by setting the minute to 0 PARK ACTION POWER UP ACTION FAN ENABLED TEMP C F the action which will be started after the idle time park time Selectable between Preset Scan Pattern Nr Tour or None defines the action which will be started after power up and self test ...

Page 10: ...e details 15 ADVANCE SETTING1 IR CUT FILTER MAX GAIN EXPOSURE COMP Mirror Flip Enables the removal of Infrared Cutter Filter IRC also known as DAY NIGHT mode with the removal of IRC the camera turns into Black White mode and has higher sensibility to low light or IR Light in the night Selectable between On Off Auto or Time Only available on camera module with IRC function improve the image quality...

Page 11: ... current day STATE activate AUTO TRACKING on this day START TIME set the time for activation END TIME set the time for stop the tracking SENSITIVE set the sensitivity for the detection TRAKING ZOOM activate auto zoom SET LIMIT set the max angle for the tracking TIME RUNNING DAY SUN TIME CHANNEL 1 START TIME 00 00 END TIME 00 00 RUNNING NONE BACK EXIT Clear the current preset Start Auto Tracking if...

Page 12: ... 0 0 HUNDA 1 0 1 1 0 0 KALATEL 0 1 0 1 0 0 LILIN 1 1 0 1 0 0 MOLYNX 0 0 1 0 0 0 PANASONIC 1 1 1 0 0 0 PELCO D P 1 0 0 0 0 0 PHILIPS 0 0 0 0 0 1 SAE 0 1 0 0 0 0 SAMSUNG 0 0 0 1 0 0 SANTACHI 0 1 1 0 0 0 UNIVISION 0 1 0 0 0 1 VCL 1 1 0 0 0 0 VICON 1 0 1 0 0 0 AD 1 0 0 0 0 1 Some products may not be available in your country please contact our distributor for more details ALARM SETTING ALARM NUMBER 00...

Page 13: ...7 Address ID 1 to 67 7 Address ID 68 to 135 ...

Page 14: ...7 Address ID 136 to 203 177 7 Address ID 204 to 255 ...

Page 15: ...t 0 4 150 per sec with Auto Flip Vario Speed control Proportional constant PT speed Outdoor 18X Outdoor 18x Outdoor 26x Outdoor 36x Indoor 18X Indoor 18x Indoor 26x Indoor 36x 9 Motion Tracking Note This option is only available if your Speed dome supported this function 1 Enter the OSD menu with CALL 95 2 Go to the option Function Setting Auto Tracking AUTO TRACKING DAY SUN STATE ON START TIME 00...

Reviews: