background image

System Setting

In system setting menu, you can modify operation and
display setting, such as dome label, temperature and
display of various value on the operational screen.

EDIT DOME LABEL

LABEL

BACK

EXIT

ENTRANCE

INITIAL  INFO

SPEED DOME V1.00
PROTOCOL:FACTORY
DOME ADDRESS:001
COMM:4800,N,8,1
BACK
EXIT

6.OSD - System Setting

6.OSD - Motion, Clear

Initial information:

Shows the information about current setting.

Dome Label:

1. use UP or DOWN to change the charactor.

2. use RIGHT to move to next char.

3. use RIGHT to move to last char and save.

4. use Left to first char and cancel.

Display setup

Dome label:
Preset label:
Zoom label:
Zone label:
Direction label:

Temperature label:

Actuvate the display for the on-screen info in operaton
mode.

the name of dome

shows the labe of every preset

shows zoom factor on screen

shows the zone name

shows the coordinates

shows the cur. temp in the speed dome

DISPLAY  SETUP

DOME LABEL

OFF

PRESET LABEL

OFF

ZOOM LABEL

ON

ZONE LABEL

OFF

DIRECTION LABEL

ON

LABEL

OFF

BACK

EXIT

TEMPERATURE

Some products may not be available in your country, please contact our distributor for more details

Some products may not be available in your country, please contact our distributor for more details

13

14

SYSTEM  SETTING

EDIT DOME  LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
PASSWORD SETUP
CLOCK SETTING
BACK
EXIT

MOTION

Motion control

AUTO FLIP

PROPORTIONAL PAN:

PARK TIME:

: Auto. Image flip in tilt range from 90° to

180°

depends on the zoom factor,

the dome will adjust the pan and tilt speed
automatically for comfortable viewing.

defines the idle time prior to start a

custom defined action( park action).The range is
from 1 to 240 minutes. This function can be
deactivated by setting the minute to 0.

PARK ACTION:

POWER UP ACTION:

FAN ENABLED:

TEMP C/F:

the action which will be started after

the idle time (park time). Selectable between Preset,
Scan, Pattern (Nr), Tour or None.

defines the action which will

be started after power up and self test. Selectable
between Auto,Preset 1, Scan, Pattern (Nr), Tour or
None. By selecting Auto, the dome will resume the
last action before power off.

Activate Fan when the dome reach the

temperature.

Switch the temperature unit between Celius and

Fahrenheit.

Advance Setting

EIS ENABLED:

E

I

S

PRESET FREEZEN:
AUTO FOCUS:
DEFOGGER:
HEAD UP:

Enable „ lectric mage

tabilization“. This

function is variable on certain camera modul.

Freeze the image immediately.

Switch ON/OFF the Auto Focus

Activate Heater/Fan on the cold temperatur.

Switch ON/OFF the proportional PT moving. Can

combine with Camera Flip function.

AUTO  FLIP

ON

PROPORTION  PAN

ON

PARK TIME

005

PARK ACTION

SCAN

POWER  UP ACTION AUTO
FAN ENABLED              040
TEMP C/F                       CENT
ADVANCE SETTING
BACK
EXIT

Clear

You can clear setting’s memory or reset the camear to
factory default. The follwing functions are supported:

- Clear Zones
- Clear all presets
- Clear all patterns
- Clear all tours
- Clear all windows
- Factory defaults

Warning

:

The clear action can not be undone.

once a item is cleared it is impossible to
retrieve the deleted setting. Please make sure
that the requested clear action is desired.

CLEAR

CLEAR ALL ZONES
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL TOURS
CLEAR ALL WINDOWS
FACTORY DEFAULTS
RESTART
BACK
EXIT

ADVANCE SETTING

EIS ENABLED                N/A
PRESET FREEZEN       OFF
AUTO FOCUS                OFF
DEFOGGER                   015C
HEAD UP

OFF

BACK
EXIT

Summary of Contents for High Speed dome Camera Series

Page 1: ...USER S MANUAL v 2 66 High Speed dome Camera Series ...

Page 2: ... IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE...

Page 3: ... 140 F and a humidity below 90 The input power source is 24V AC 50 60Hz and requires 2500mA outdoor models Do not expose the indoor model of dome camera to water or moisture not try to operate it in wet areas 2 FEATURES 1 2 Some products may not be available in your country please contact our distributor for more details Some products may not be available in your country please contact our distrib...

Page 4: ...nt damages caused by high voltage pulse such as lightning strike below 1500 This appliance meets the Ip66 standard for water and dust proof Do not install the in door model for out door application which is not designed with water protection Make sure that the installation is protected from long time water drop or spatter which may damage the appliance Make sure that the enviroment of installation...

Page 5: ...hnology Depends on the cable typeand baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 4oom 4800 bps 1700m 9600 bps 19200 bps Baud Rate Max Distance Due the environmental interferences such as eletromagnetic and induction fields or number of connected appliance on the RS 485 bus the transmission...

Page 6: ...th 120 resistor on both ends Following picture illustrates the connection methods please note that a daisy chain connection type shall not exceed 7 meters Ω 120Ω Resistor Device 2 Device 3 Device 1 120Ω Resistor RS 485 RS 485 RS 485 RS 485 Termination on Termination off Termination off How to turn on termination on the high speed dome camera The termination switch is located on the rear side of th...

Page 7: ...After unpaking and during the installation the core unit should be installed as following Installing the core unit by pushing into the housing please note the position of connector For releasing please press the lever lock to core and pull off the unit Lever Lock Connector Interface Power LED Metal Clip WARNING Do not pull or hold the connector interface with force It is design only to connect the...

Page 8: ... NUMBER 1 PROGRAM PATTERN RUN PATTERN CLEAR PATTERN EDIT PATTERN LABEL BACK EXIT EDIT T O U R P0 S P0 S P0 S 00 0 00 00 0 00 00 0 00 TM TM TM B A C K E X I T 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 Z O N E S ZONES NUMBER 1 SET LEFT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL BACK EXIT DOME LABEL OFF PRESET LABEL OFF ZOOM LABEL O ZONE LAB...

Page 9: ...es the idle time prior to start a custom defined action park action The range is from 1 to 240 minutes This function can be deactivated by setting the minute to 0 PARK ACTION POWER UP ACTION FAN ENABLED TEMP C F the action which will be started after the idle time park time Selectable between Preset Scan Pattern Nr Tour or None defines the action which will be started after power up and self test ...

Page 10: ...e details 15 ADVANCE SETTING1 IR CUT FILTER MAX GAIN EXPOSURE COMP Mirror Flip Enables the removal of Infrared Cutter Filter IRC also known as DAY NIGHT mode with the removal of IRC the camera turns into Black White mode and has higher sensibility to low light or IR Light in the night Selectable between On Off Auto or Time Only available on camera module with IRC function improve the image quality...

Page 11: ... current day STATE activate AUTO TRACKING on this day START TIME set the time for activation END TIME set the time for stop the tracking SENSITIVE set the sensitivity for the detection TRAKING ZOOM activate auto zoom SET LIMIT set the max angle for the tracking TIME RUNNING DAY SUN TIME CHANNEL 1 START TIME 00 00 END TIME 00 00 RUNNING NONE BACK EXIT Clear the current preset Start Auto Tracking if...

Page 12: ... 0 0 HUNDA 1 0 1 1 0 0 KALATEL 0 1 0 1 0 0 LILIN 1 1 0 1 0 0 MOLYNX 0 0 1 0 0 0 PANASONIC 1 1 1 0 0 0 PELCO D P 1 0 0 0 0 0 PHILIPS 0 0 0 0 0 1 SAE 0 1 0 0 0 0 SAMSUNG 0 0 0 1 0 0 SANTACHI 0 1 1 0 0 0 UNIVISION 0 1 0 0 0 1 VCL 1 1 0 0 0 0 VICON 1 0 1 0 0 0 AD 1 0 0 0 0 1 Some products may not be available in your country please contact our distributor for more details ALARM SETTING ALARM NUMBER 00...

Page 13: ...7 Address ID 1 to 67 7 Address ID 68 to 135 ...

Page 14: ...7 Address ID 136 to 203 177 7 Address ID 204 to 255 ...

Page 15: ...t 0 4 150 per sec with Auto Flip Vario Speed control Proportional constant PT speed Outdoor 18X Outdoor 18x Outdoor 26x Outdoor 36x Indoor 18X Indoor 18x Indoor 26x Indoor 36x 9 Motion Tracking Note This option is only available if your Speed dome supported this function 1 Enter the OSD menu with CALL 95 2 Go to the option Function Setting Auto Tracking AUTO TRACKING DAY SUN STATE ON START TIME 00...