Avtech TemPageR 3E User'S Manual & Reference Manual Download Page 22

18 

         

AVTECH Inc.

Additional Screens And Interfaces 

 

 

 

 

 

 

                

TemPageR 3E

About

The TemPageR 3E ‘About’ screen provides general links and contact information for AVTECH sales, support 

and websites. The firmware version that is currently installed on the TemPageR 3E unit will also be listed with 

the date released directly below. The link entitled ‘Click Here To Check For Updates’ can be used to check if 

the firmware version installed on the TemPageR 3E unit is the most current (requires internet access). 

Web Interface

The TemPageR 3E web interface can be used to view current sensor status on the TemPageR 3E unit. 

The web interface is accessed by selecting the TemPageR 3E unit in the AVTECH Device Discovery 

Utility and clicking the ‘Web’ button or by typing the IP address of the TemPageR 3E unit in the location 

bar of a web browser, once it has been installed properly on your network.

NOTE: If the ‘Loading Sensor Data’ indicator remains on the page, be sure that you do not have a proxy or Microsoft ISA 

server soliciting traffic and requests from the TemPageR 3E unit. 

Below the menu bar on the TemPageR 3E is the device name, date and time display, and MAC address display. 

NOTE: If the date displayed is ‘2/14/36’, the TemPageR 3E is currently unable to connect to a time server. Please verify that 

the network has a connection to the internet and that NTP requests on UDP port 123 are not blocked. If the network does not 

have a connection to the internet or use of a local time server is desired, an IP address for a valid NTP time server can be 

entered in the ‘Time Server IP’ field on the ‘Advanced’ tab of the ‘Settings’ screen.

To the right of the date and time is the product name and firmware version number. This acts as a link that 

can be used to determine if the firmware version installed on the unit is the most current version. An internet 

connection is required for the firmware version check. The firmware is always current as of the time of 

shipment so there is seldom a need to upgrade shortly after purchase of the TemPageR 3E. The exception 

would be those occasions where a new version of the firmware has just coincidentally been released.

Using Trace Output

Trace output is very useful for troubleshooting sending SMTP email and other issues. The trace output 

will show the communication between TemPageR and the configured mail server to show what might 

be preventing email from being sent. It will also show other information including the current version 

number, IP address, MAC address, requests to the web pages and much more.

To configure trace output in TemPageR, click ‘Settings’ and then ‘Advanced’. Select the ‘Enable 

Tracing’ checkbox and enter the desired port number in the ‘Trace Port’ field. Save the settings by 

clicking the ‘Accept Changes’ button, then ‘Save Settings’. To view the trace output, click ‘Settings’ and 

then ‘Advanced’. Click ‘View Tracing Output’ to open a trace window. When the trace window loads, 

click ‘Connect’ to begin viewing the live trace output.  Once trace is running, try to replicate any issues 

that are occurring so they are captured in the trace output. If having issues sending email, send a test 

email while viewing the trace output. Once captured, copy and paste the trace output into a text editor to 

save the contents of the trace.

Help 

The TemPageR 3E ‘Help’ screen provides links to online support and information resources for the 

TemPageR 3E as well as information regarding telephone and email support. Directly below the 

‘TemPageR 3E Help’ heading will be the current firmware version that is installed on the TemPageR 

3E unit and its release date. The link entitled ‘Click Here To Check For Updates’ can be used to check 

if the firmware version installed on the TemPageR 3E unit is the most current (requires internet access). 

The additional support information provided on this screen is presented in the order that it should be 

followed in the event that you have a technical question regarding the TemPageR 3E or if you are 

experiencing a situation where assistance is desired. 

Summary of Contents for TemPageR 3E

Page 1: ...World s Most Popular Real Time Temperature Monitor For Physical IT Facilities Environment Monitoring TemPageR 3E Phone Fax Web 401 628 1600 401 628 1601 AVTECH com User s Guide Reference Manual 120914...

Page 2: ...owledgements AVTECH the AVTECH Logo AVTECH Software the AVTECH System Manager Character AVTECH com AVTECHSoftware com Device Discovery Device ManageR Environment Alarm Environment Monitoring Made Easy...

Page 3: ...ect Included Sensors And Accessories 8 Step 5 Check TemPageR 3E Firmware Version 8 Configuration And Setup Screens 9 Alert Methods 9 Email 9 Initial Email Setup 10 Test Email 10 Email To SMS 10 SNMP 1...

Page 4: ...Sensor 15 Dry Contacts 15 Additional Screens And Interfaces 16 Network 16 Security 16 Advanced 17 Using Trace Output 18 Help 18 About 19 Web Interface 19 Advanced Topics 21 Upgrading Firmware 21 Rese...

Page 5: ...include email email to SMS actions such as toggling Signal Tower LEDs for Room Alert models sending URL Web Requests and more If you have not looked at Device ManageR before take a look because it tr...

Page 6: ...y email to computers mobile phones BlackBerrys pagers PDAs and more By having another monitoring application like AVTECH s Device ManageR monitor TemPageR there are additional options for logging grap...

Page 7: ...onal sensors that are not mentioned above instructional material explaining the proper setup of that component should be included with it If you cannot find the proper instructional materials check th...

Page 8: ...other end of the Ethernet cable to an open port on the switch or router that will give the TemPageR 3E unit access to your network Next locate the AVTECH 5v 1A Power Adapter and plug it into a surge...

Page 9: ...ted to be performed on multiple units i e all selected units simultaneously The Set IP button is used to assign a static IP address gateway IP address subnet mask and DNS server IP address or to set t...

Page 10: ...re a computer on the local network to act as a time server for other devices Visit AVTECH s Frequently Asked Questions FAQs to learn more The Save Settings feature can be used to download the current...

Page 11: ...P address assigned to the computer i e IP address of computer 192 168 2 3 IP address of TemPageR 3E 192 168 2 4 If the IP address of the TemPageR 3E unit is still not updated continue with steps 7 9 7...

Page 12: ...Temperature Sensor provides a real time digital temperature reading at the location of the temperature probe Position the sensor in the desired location running the sensor cable back to the TemPageR...

Page 13: ...pliant and can be accessed by any application that can issue a SNMP Get request Other monitoring applications can therefore be used to perform SNMP Get requests and receive SNMP Traps Email Email aler...

Page 14: ...ings NOTE If a domain name is entered in the Mail Server Address field the TemPageR 3E unit must be assigned static IP settings and have a DNS server IP address set Test Email A test email can be sent...

Page 15: ...may confirm it and post it online for the convenience of other users SNMP The TemPageR 3E unit is fully SNMP compliant and can be monitored by applications capable of performing an SNMP Query or Get r...

Page 16: ...scheduling and more Device ManageR also allows for Actions on Alert Alert clear conditions such as toggling Signal Tower LEDs Room Alert models Send Web URL requests sending screenshots from AXIS came...

Page 17: ...field below the Sensor Label High and low thresholds for the temperature are entered in the High and Low columns Temperature thresholds must be entered in the temperature scale selected on the Advance...

Page 18: ...es Fahrenheit and or 55 to 125 degrees Celsius Accuracy is within 0 5 degrees Its non conductive casing makes it a perfect sensor for monitoring the temperature of fluids in extreme environments walk...

Page 19: ...sensor that connects to one of the switch sensor contact sets via a low voltage 2 wire cable Smoke Sensor RMA SS1 SEN The AVTECH Smoke Sensor allows a real time notification of the presence of smoke...

Page 20: ...address and subnet mask in the appropriate fields When finished click the Accept Change button then Save Settings NOTE If configuring static IP settings on the TemPageR 3E unit be sure that the setti...

Page 21: ...ime display daylight savings time setting time server IP address and trace configuration options The temperature scale selected in the Temperature Scale drop down will be the default temperature scale...

Page 22: ...he live trace output Once trace is running try to replicate any issues that are occurring so they are captured in the trace output If having issues sending email send a test email while viewing the tr...

Page 23: ...proxy or Microsoft ISA server soliciting traffic and requests from the TemPageR 3E unit Below the menu bar on the TemPageR 3E is the device name date and time display and MAC address display NOTE If t...

Page 24: ...will correspond with the Fahrenheit or Celsius scale selected on the Advanced tab of the Settings screen Below these two rows is the sensor display area The display for each sensor within the sensor...

Page 25: ...ere the TemPageR 3E Firmware Update file was saved select it and click the Upload button A dialog will then load asking for confirmation of the firmware upload Click Ok to upload the TemPageR 3E Firmw...

Page 26: ...ter with a single Ethernet adapter 2 Download the most current version of the TemPageR 3E Firmware Update file from the Downloads section of the AVTECH com website 3 Connect the TemPageR 3E unit to th...

Page 27: ...al database Device ManageR also has the ability to discover any Axis network camera and acts as a single interface for viewing camera images for multiple cameras distributed across the network Cameras...

Page 28: ...Protect Your IT Facility Don t Wait Until It s To Late AVTECH com...

Reviews: