CONNECTION
2
2. CONNECTION
2.1 Hard Disk Installation
Two RAID 5 arrays could be built on this device:
HDD 1 ~ 5 as RAID5 array 1, and
HDD 6 ~ 10 as RAID5 array 2
Before installing hard disks, make sure:
At least 3 hard disks shall be prepared for one RAID 5 array for the RAID5 function to work properly.
The hard disks are new to use. If no, please do a low format for the used hard disk to restore it to its default
status.
The volume of each hard disk is the same.
Use
ONLY
the hard disk designed especially for surveillance to ensure the device works properly.
The same brand and series for hard disks are strongly recommended.
Note:
It’s necessary to install a hard disk first before firmware upgrade to ensure the upgrade process
works properly.
Step1: Remove the cover by loosening the left side of the cover’s screws.
HDD2
HDD3
HDD4
HDD5
HDD6
HDD7
HDD8
HDD9
HDD10
Step2: Find the hard disk connector and HDD tray in the device. Press the button of the HDD tray as indicated
below and remove it.
HDD Tray: Press to remove