background image

INSTRUCTIONS

MODEL AVD

20 V

PP

, 1 MHz, FIXED-TUNED

MONOCYCLE GENERATOR MODULE

SERIAL NUMBER: ____________

A V T E C H     E L E C T R O S Y S T E M S     L T D .

N A N O S E C O N D   W A V E F O R M   E L E C T R O N I C S

S I N C E   1 9 7 5

P.O. BOX 265

OGDENSBURG,  NY

U.S.A. 13669-0265

TEL: 888-670-8729 (USA & Canada) or +1-613-686-6675 (Intl)

FAX: 800-561-1970 (USA & Canada) or +1-613-686-6679 (Intl)

[email protected]    -    http://www.avtechpulse.com/

X BOX 5120, LCD MERIVALE

OTTAWA, ONTARIO

CANADA    K2C 3H5

Summary of Contents for AVD series

Page 1: ...T E M S L T D N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P O BOX 265 OGDENSBURG NY U S A 13669 0265 TEL 888 670 8729 USA Canada or 1 613 686 6675 Intl FAX 800 561 1970...

Page 2: ...ace said defective item This warranty does not apply to units which have been dissembled modified or subjected to conditions exceeding the applicable specifications or ratings This warranty is the ext...

Page 3: ...DECLARATION OF CONFORMITY 6 DIRECTIVE 2002 95 EC RoHS 7 DIRECTIVE 2002 96 EC WEEE 7 BASIC TEST ARRANGEMENT 8 DC POWER SUPPLY 8 GENERAL OPERATING NOTES 8 PERFORMANCE CHECK SHEET 10 Manual Reference fi...

Page 4: ...com appnote techbrief13 for information about center frequency measurements The AVD can operate at repetition rates of up to 1 MHz The AVD must be triggered by an external TTL pulse 50 ns applied to t...

Page 5: ...A max to back panel terminals Trigger required 5 Volt 50 to 500 ns TTL Connectors In Out SMA Power solder terminals Power requirement 15 Volt 200 mA Dimensions H x W x D 43 x 66 x 107 mm 1 7 x 2 6 x 4...

Page 6: ...g Also check that your load is adequately shielded It may be necessary to enclose the load in a metal enclosure If any of the connectors on the instrument are unused they should be covered with shield...

Page 7: ...ies to Directive 2002 96 EC categories 1 7 and 10 as stated in the Article 2 Scope section of Directive 2002 95 EC DIRECTIVE 2002 96 EC WEEE European customers who have purchased this equipment direct...

Page 8: ...lse generator output signal attenuators cables connectors etc should exceed 10 GHz 2 The use of 40 dB attenuator on the output will ensure a peak input signal to the sampling scope of much less than 1...

Page 9: ...50 Volts subject to a maximum current rating of 250 mA Option 4 WARNING The module may fail if triggered at a PRF greater than 1 MHz or 3 MHz for units with the F3 option 9...

Page 10: ...PERFORMANCE CHECK SHEET 10...