and that this pulse generator meets the intent of the Low Voltage Directive 72/23/EEC 
as amended by 93/68/EEC. Compliance pertains to the following specifications as 
listed in the official Journal of the European Communities:

EN 61010-1:2001

Safety requirements for electrical equipment for 
measurement, control, and laboratory use

DIRECTIVE 2002/95/EC (RoHS)

This instrument is exempt from Directive 2002/95/EC of the European Parliament and 
of the Council of 27 January 2003 on the Restriction of the use of certain Hazardous 
Substances (RoHS) in electrical and electronic equipment. Specifically, Avtech 
instruments are considered "Monitoring and control instruments" (Category 9) as 
defined in Annex 1A of Directive 2002/96/EC. The Directive 2002/95/EC only applies to 
Directive 2002/96/EC categories 1-7 and 10, as stated in the "Article 2 - Scope" section
of Directive 2002/95/EC.

DIRECTIVE 2002/96/EC (WEEE)

European customers who have purchased this equipment directly from Avtech will have
completed a “WEEE Responsibility Agreement” form, accepting responsibility for 
WEEE compliance (as mandated in Directive 2002/96/EC of the European Union and 
local laws) on behalf of the customer, as provided for under Article 9 of Directive 
2002/96/EC.

Customers who have purchased Avtech equipment through local representatives 
should consult with the representative to determine who has responsibility for WEEE 
compliance. Normally, such responsibilities with lie with the representative, unless 
other arrangements (under Article 9) have been made.

Requirements for WEEE compliance may include registration of products with local 
governments, reporting of recycling activities to local governments, and financing of 
recycling activities.

7

Summary of Contents for AVD series

Page 1: ...T E M S L T D N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P O BOX 265 OGDENSBURG NY U S A 13669 0265 TEL 888 670 8729 USA Canada or 1 613 686 6675 Intl FAX 800 561 1970...

Page 2: ...ace said defective item This warranty does not apply to units which have been dissembled modified or subjected to conditions exceeding the applicable specifications or ratings This warranty is the ext...

Page 3: ...DECLARATION OF CONFORMITY 6 DIRECTIVE 2002 95 EC RoHS 7 DIRECTIVE 2002 96 EC WEEE 7 BASIC TEST ARRANGEMENT 8 DC POWER SUPPLY 8 GENERAL OPERATING NOTES 8 PERFORMANCE CHECK SHEET 10 Manual Reference fi...

Page 4: ...com appnote techbrief13 for information about center frequency measurements The AVD can operate at repetition rates of up to 1 MHz The AVD must be triggered by an external TTL pulse 50 ns applied to t...

Page 5: ...A max to back panel terminals Trigger required 5 Volt 50 to 500 ns TTL Connectors In Out SMA Power solder terminals Power requirement 15 Volt 200 mA Dimensions H x W x D 43 x 66 x 107 mm 1 7 x 2 6 x 4...

Page 6: ...g Also check that your load is adequately shielded It may be necessary to enclose the load in a metal enclosure If any of the connectors on the instrument are unused they should be covered with shield...

Page 7: ...ies to Directive 2002 96 EC categories 1 7 and 10 as stated in the Article 2 Scope section of Directive 2002 95 EC DIRECTIVE 2002 96 EC WEEE European customers who have purchased this equipment direct...

Page 8: ...lse generator output signal attenuators cables connectors etc should exceed 10 GHz 2 The use of 40 dB attenuator on the output will ensure a peak input signal to the sampling scope of much less than 1...

Page 9: ...50 Volts subject to a maximum current rating of 250 mA Option 4 WARNING The module may fail if triggered at a PRF greater than 1 MHz or 3 MHz for units with the F3 option 9...

Page 10: ...PERFORMANCE CHECK SHEET 10...

Reviews: