- 25 -
SW2 - ADDRESS OnE PA HP and OnE DT HP
Sensor
DIP1 DIP2 DIP3 DIP4 DIP5
Sensor
DIP1 DIP2 DIP3 DIP4 DIP5
Sensor
DIP1 DIP2 DIP3 DIP4 DIP5
1
ON
ON
ON
ON
ON
12
OFF
OFF
ON
OFF
ON
23
ON
OFF
OFF
ON
OFF
2
OFF
ON
ON
ON
ON
13
ON
ON
OFF
OFF
ON
24
OFF
OFF
OFF
ON
OFF
3
ON
OFF
ON
ON
ON
14
OFF
ON
OFF
OFF
ON
25
ON
ON
ON
OFF
OFF
4
OFF
OFF
ON
ON
ON
15
ON
OFF
OFF
OFF
ON
26
OFF
ON
ON
OFF
OFF
5
ON
ON
OFF
ON
ON
16
OFF
OFF
OFF
OFF
ON
27
ON
OFF
ON
OFF
OFF
6
OFF
ON
OFF
ON
ON
17
ON
ON
ON
ON
OFF
28
OFF
OFF
ON
OFF
OFF
7
ON
OFF
OFF
ON
ON
18
OFF
ON
ON
ON
OFF
29
ON
ON
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
ON
19
ON
OFF
ON
ON
OFF
30
OFF
ON
OFF
OFF
OFF
9
ON
ON
ON
OFF
ON
20
OFF
OFF
ON
ON
OFF
31
ON
OFF
OFF
OFF
OFF
10
OFF
ON
ON
OFF
ON
21
ON
ON
OFF
ON
OFF
32
OFF
OFF
OFF
OFF
OFF
11
ON
OFF
ON
OFF
ON
22
OFF
ON
OFF
ON
OFF
By DEFAULT, the sensors are supplied with DIP SWITCHES 1 to 5 set to OFF (sensor 32)
O
N
1
2
3
4
5
6
7
8
O
N
1
2
3
4
5
6
7
8
SW2
- +
DADB
RV1
RV2
TAMPER
L1
L2
OnE PA HP and OnE DT HP
TERMINAL BLOCK
-
Negative power
+
12 V positive power =
DA
RS485 serial: For connection to the dedicated input of the satellite XSATHPs or
directly to the RS485 serial of the controllers prepared
DB
Exclusively for the connection of the DA and DB serial communication
terminals, we recommend shielded cables with a section of 0.5 mm² each,
while the section of the power cables (
+
and
-
) of the equipment connected to
the serial port must be sized according to the type of system, according to the
experience of the installer.
Trimmer RV1 - Microwave range (Models One DT and OnE DT HP only)
Trimmer for adjusting the microwave range (turning it counterclockwise gives the minimum range).
Trimmer RV2 - Infrared range
Trimmer for adjusting the infrared range (turning it counterclockwise gives the minimum range).
Common configurations OnE PA, OnE DT, OnE PA HP e OnE DT HP
Depending on the setting of DIP6 of bank SW2, the yellow LED can indicate the status of the microwave or the
status of the anti-masking circuit.
In addition to trimmer RV1 for adjusting the microwave range, the sensor has a trimmer RV2 for adjusting the range
of the infrared
LED
BLUE
(LD1)
Flashes:
Steady on:
alternating with the yellow LED for about 60 seconds on first power-on
general alarm signal
YELLOW
(LD2)
DIP 6 of SW2 to OFF
DIP 6 of SW2 to ON
Flashes:
Steady on:
Fast flashing:
Slow flashing:
Steady on:
alternating with the blue LED for about 60 seconds on first power-on
Anti-masking signal
Anti-masking pre-alarm signal
Anti-masking calibration after closing the cover
Microwave alarm signal
SW2 - FUNCTIONS
DIP 6
ON
Yellow LED
displays status
of the Microwave
(Model OnE DT HP
only)
OFF
DEFAULT
Yellow LED
displays status of the
Anti-mask
DIP 7
ON
Anti-mask
Active
OFF
DEFAULT
Anti-mask
Disabled
DIP 8
ON
Tamper
Accelerometer
enabled
OFF
DEFAULT
Tamper
Accelerometer
excluded
E
N
G
Summary of Contents for ONE DT
Page 11: ... 11 I T A ...
Page 12: ... 12 I T A ...
Page 13: ... 13 I T A ...
Page 27: ... 27 E N G ...
Page 28: ... 28 E N G ...
Page 29: ... 29 E N G ...
Page 43: ... 43 F R A ...
Page 44: ... 44 F R A ...
Page 45: ... 45 F R A ...
Page 59: ... 59 E S P ...
Page 60: ... 60 E S P ...
Page 61: ... 61 E S P ...
Page 75: ... 75 N L D ...
Page 76: ... 76 N L D ...
Page 77: ... 77 N L D ...