- 19 -
E
N
G
General characteristics
OnE DT and OnE DT HP
are dual-technology, microprocessor-controlled volumetric sensors in which the combination
of a
Fresnel passive infrared lens
and a
planar microwave
create very effective protection against false alarms
in critical environments. OnE DT and OnE DT HP and are recommended for external protection.
OnE PA, OnE PA HP and OnE PA WS
are microprocessor-controlled volumetric sensors with
Fresnel passive
infrared lens
.
OnE PA WS
integrates a
single-frequency radio transmission module
that is
compatible with receivers and
controllers
from
AVS Electronics.
All models are equipped with:
-
Thermal compensation,
the sensor automatically adjusts the range as the ambient temperature changes,
however, despite this, the performance of the sensor can vary significantly depending on the particular tempe-
rature interval.
-
Accelerometer,
for the reporting tear and disorientation (does not detect vibration). Any
unauthorized removal
is signalled by the sensor as a tamper (option enabled by DEFAULT).
-
Anti-masking,
to detect obstacles that are placed to cover the sensor.
Connections (Models OnE PA, OnE DT, OnE PA HP and OnE DT HP)
The connections of the models
OnE PA
and
OnE DT
are made through a C-NC contact for signalling the Alarm and
a T-T contact for the signalling of the Tamper.
The connections of the models
OnE PA HP
and
OnE DT HP
are made through
RS485 serial,
to the
XSATHP
satellite or directly to the
AVS controllers provided.
Configuration
Models
OnE PA, OnE DT
and
OnE PA WS
are configured through the on-board
DIP SWITCHES
.
Models
OnE PA HP
and
OnE DT HP
can be configured through the on-board
DIP SWITCHES
or with the
XWIN
software.
First Power-On
The sensor is blocked for about 60 seconds, during which the LEDs flash and the anti-masking circuit performs a
self-regulation. At this stage, it is essential that the cover be regularly installed to allow the sensor to regulate itself
to the correct values.
AND operation (Models OnE DT and OnE DT HP)
The microprocessor constantly analyzes the signals coming from the infrared and microwave sections, which are
thus compared with the preset parameters; only when both technologies go into alarm within a time interval of about
10 seconds, will the alarm relay be activated and the blue LED light up.
ANTI-MASKING Operation (Not active with TAMPER OPEN):
When the sensor detects an obstacle, a time delay is activated during which the yellow LED flashes. If, at the end
of this time, the obstacle is not removed or the sensor goes into alarm, the Anti-mask signal is activated.
NOTE: However, this function does not guarantee that the sensor cannot be masked.
NOTE:
Keep the sensor lens free of dust or other filtering material that could alter its functioning.
NOTE: the instructions regarding the YELLOW LED refer to all models except the OnE PA WS.
INFRARED ANTI-MASKING Function
The infrared anti-masking circuit, which is present in all sensor models, consists of an active infrared RX receiver
and TX transmitter located above and below the PIR sensor, which detects obstacles (adhesive tape and almost all
paints) placed in front of the sensor up to a distance of about 10 cm. The signal is generated after about 30 seconds
from the detection of the obstacle, if the sensor does not generate an alarm in the meantime.
The signal is reset upon the removal of the obstacle.
MICROWAVE ANTI-MASKING Function
The microwave anti-masking circuit, present in models
OnE DT
and
OnE DT HP
, provides an alarm signal if
microwave reflective material (such as metal, wood, plastic, etc.) is brought within less than 1 metre. The signal is
generated after about 1 minute from the detection of movement within 1 metre, if the sensor has not generated an
alarm in the meantime.
The signal is reset as soon as an alarm is generated.
DIRTY LENS operation (Models OnE PA HP and OnE DT HP)
When the Anti-mask circuit detects that the average value of the signal stored in a certain time interval has undergone
a change of about 20%, the signal is sent to the controller and the
yellow LED
flashes slowly.
To restore the Lens dirty signal after cleaning the lens, you must power the sensor off and on.
Summary of Contents for ONE DT
Page 11: ... 11 I T A ...
Page 12: ... 12 I T A ...
Page 13: ... 13 I T A ...
Page 27: ... 27 E N G ...
Page 28: ... 28 E N G ...
Page 29: ... 29 E N G ...
Page 43: ... 43 F R A ...
Page 44: ... 44 F R A ...
Page 45: ... 45 F R A ...
Page 59: ... 59 E S P ...
Page 60: ... 60 E S P ...
Page 61: ... 61 E S P ...
Page 75: ... 75 N L D ...
Page 76: ... 76 N L D ...
Page 77: ... 77 N L D ...