Page 30 - 9. System specification
A2K-T4-V2.2 27/08/2014 11:19:00
C H A P T E R E I G H T
9.
System specification
The figures below give the specification of the standard ART2000 system.
Power Ratings
Minimum
Maximum
Mains input voltage (phase -
neutral)*
110V/220V
120V/240V
Mains input frequency
42Hz
72Hz
Current drawn per phase
274A
Current per channel
16A/32A/63A
*System is manufactured for either 110V or 240V
Environmental ratings
Minimum
Maximum
Ambient temperature
0°C
40°C
Internal heatsink temperature
70°C
Relative humidity
-
90% non-
condensing
Fan cooling airflow
(cubic ft/min)
Minimum
Maximum
Normal operation
80 CFM
100 CFM
Maximum load
850 CFM
Generated heat
typical
16A Channel @100%
25W
85 Btu
32A Channel @100%
55W
187 Btu
63A Channel @100%
125W
426 Btu
Physical information
Dimensions (all rack lids fitted)
580 x 1005 x 1180 mm LxDxH
Weight
198Kg (48x16A)
Channel/Phase information
12
channel
module
6
channel
module
3
channel
module
Red phase
1,4,7,10
1,3
1
Yellow phase
2,5,8,11
2,4
2
Blue phase
3,6,9,12
3,5
3