SkyEdgeII Modem
6
Figure 5 – Configuration Core Keyword Skyedge
Long name
Level Category
Type
Value
Range
Documentation
SkyEdgeII Com
Port
4
String
System
-
The communications port used for serial
connection or IP address of the Serial to
Ethernet server for Ethernet connection.
SkyEdgeII Com
Port Settings
4
String
System
-
The computer settings for the com port, in the
form of Baud, Data, Stop & Parity Bits (ie: 9600 8
1 0) for serial connection, or the port number of
the Serial to Ethernet server for Ethernet
connection.
SkyEdgeII Noise
Sample Time
4
Integer
System
0 to
60000
Sample time in MS for detecting signal noise
SkyEdgeII
Gradient Sample
Time
4
Integer
System
0 to
60
Sample time in seconds for detecting signal
gradient
SkyEdgeII Lat
Long Send Time
4
String
Modules
-
Amount of time in seconds between sending
lat/long messages to the modem
SkyEdgeII Manual
Latitude
1
String
Modules
-
The Latitude sent to the modem when SkyEdgeII
GPS Override is 1
SkyEdgeII Manual
Longitude
1
String
Modules
-
The Longitude sent to the modem when
SkyEdgeII GPS Override is 1
SkyEdgeII
Remove Negative
SNR
4
String
Modules
-
0 = Include negative numbers from modem
1 = Remove negative numbers from modem
SkyEdgeII
Override GPS
4
String
Modules
-
0 = Use controller supplied GPS Coordinates
1 = Use manual GPS Coordinates
SkyEdgeII Poll
Rate
4
String
Modules
-
The rate at which the controller requests data
from the modem (1-10 samples per second)