NOTE:
The RJ-50-to-GPI terminal block adapter has eight positions that can each be used for
setting Tally and loading presets.
By default, the terminal block is used to turn on/off the Tally for each window:
– Position 1 + GND = turns on main Tally for window 1.
– Position 2 + GND = turns on secondary Tally for window 1.
– Position 3 + GND = turns on main Tally for window 2.
– Position 4 + GND = turns on secondary Tally for window 2.
– Position 5 + GND = turns on main Tally for window 3.
– Position 6 + GND = turns on secondary Tally for window 3.
– Position 7 + GND = turns on main Tally for window 4.
– Position 8 + GND = turns on secondary Tally for window 4.
Preset Time
By using the RJ-50-to-GPI terminal block, allows you to set the count up or
count down the preset time (
Index 1
~
8
) that can be recalled using GPIO.
TSL
NOTE:
Make sure that you have selected the
TSL
configuration on the previous setting
under
Group Parameter
(see previous section).
60