16
© 2008 Directed Electronics. All rights reserved.
H1/4
WHITE/BLUE
(-) ACTIVATION INPUT
This input comes from the factory set to 1 activation pulse. This means
that it is necessary to have 1 ground pulse on the white/blue wire for
the remote start to activate or to deactivate. The same holds true for the
remote control activation when set to a two pulse setting it is necessary
to press the
button twice for the remote start to activate or deacti-
vate.
Note:
When the activation pulse count can be programmed to 1, 2, or
3 pulses when changed it will affect both activation inputs; the White/
Blue wire and the remote control activation.
H1/5
ORANGE
(-) GROUND WHEN LOCKED OUTPUT
This wire supplies a (-)500 mA ground as long as the system is locked
and when the remote start is activated. (This feature can be turned off
by programming the anti-grind option Off). This output ceases as soon
as the system is unlocked. The GWA can be hooked up to an optional
starter kill/anti-grind relay control module, a voice module or any ac-
cessory that requires a ground when armed.