EX5000 Installation Manual
P/N 600-00073 Rev 24
- 66 -
5.9.2 Roll Trim Adjustment
➤
To adjust the Roll Trim Adjustment:
1.
From the Maintenance Mode Page, select
Setup Radar
.
2.
From the Radar Setup page. select
Roll Trim.
3.
The Roll Trim value appears on the Radar screen and can be modified by the Roll Trim control
knob.
4.
When you are done, press
Back
to save the new Roll Trim setting and return to the Radar Setup
Page.
5.
Press
Save
from the Radar Setup Page. Press
Cancel
to exit without saving changes.
6.
Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press
Restart System
.
5.9.3 RADAR Checkout
Perform a functional test of the RADAR system in accordance with manufacturers instructions. See the
MFD Pilot Guide
for display operation.
5.9.4 RADAR Sensor Communications Troubleshooting
If there is a communication or data error between the RADAR sensor and the MFD, one of the
following messages will display on the bottom of the screen.
Table 25: Radar Sensor Error Messages
Message
Meaning/Action
Radar Sensor Data Is Invalid
Data received from the RADAR sensor system can not be used by the
EX5000
■
Cycle power on the EX5000.
■
See RADAR Sensor Installation and User’s Manual for troubleshooting
guidance.
Radar Sensor Has Failed
The RADAR sensor system has reported an error.
■
Check R/T configuration module error log.
■
See the RADAR Sensor Installation and User’s Manual for
troubleshooting guidance.
Radar Sensor Is Not Communicating
Communication of return data from the RADAR sensor to the MFD has
been lost.
■
Verify that the RADAR sensor is turned on and valid.
■
Verify that the EX5000 is properly seat in its tray.
■
Verify system wiring.
Invalid GPS Data and Radar is ON
The RADAR is ON and the EX5000 has no ground speed data available
from the GPS/FMS.
■
Verify the GPS/FMS is ON and valid.
■
Verify system wiring.
■
See the RADAR Sensor Installation and User’s Manual for
troubleshooting guidance.
Radar Automatic Standby Disabled
The RADAR is ON, the EX5000 RADAR automatic standby mode is
disabled, and the EX5000 has no ground speed data available from the
GPS/FMS.
■
Verify the GPS/FMS is ON and valid.
■
Verify system wiring.
■
See the RADAR Sensor Installation and User’s Manual for
troubleshooting guidance.
Summary of Contents for 700-00004 Series
Page 2: ......
Page 4: ...EX5000 Installation Manual P N 600 00073 Rev 24 ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 10: ...EX5000 Installation Manual P N 600 00073 Rev 24 viii This page intentionally blank ...
Page 40: ...EX5000 Installation Manual P N 600 00073 Rev 24 30 Figure 6 EX5000 Landscape Front View ...
Page 92: ...EX5000 Installation Manual P N 600 00073 Rev 24 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...EX5000 Installation Manual P N 600 00073 Rev 24 88 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...EX5000 Installation Manual P N 600 00073 Rev 24 94 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 115: ...EX5000 Installation Manual P N 600 00073 Rev 24 105 Appendix J Wiring Diagram GPS FMS ...
Page 117: ...EX5000 Installation Manual P N 600 00073 Rev 24 107 Appendix L Wiring Diagram Traffic Sensors ...
Page 118: ...EX5000 Installation Manual P N 600 00073 Rev 24 108 Appendix M Wiring Diagram TAWS ...
Page 119: ...EX5000 Installation Manual P N 600 00073 Rev 24 109 Appendix N Wiring Diagram Radar Sensor ...
Page 120: ...EX5000 Installation Manual P N 600 00073 Rev 24 110 Appendix O Wiring Diagram Engine Sensors ...
Page 126: ...EX5000 Installation Manual P N 600 00073 Rev 24 116 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...EX5000 Installation Manual P N 600 00073 Rev 24 120 This page intentionally left blank ...
Page 131: ......