Lightning Sensor Noise Mode
When operating the Lightning sensor (WX-500 only) in Noise Monitor mode, the Lightning button on
the Map page will display “Noise” as the current Lightning state.
➥
Do not press the button in this state, or it may suppress lightning display unnecessarily.
See the operating guide for the Lightning Sensor for more information.
If no lightning strikes are shown at all during noise testing, press the button until it says Display Off,
then press once more to return to the proper Noise mode display.
Lightning Sensor is Not Communicating
Communication between the Lightning sensor to the MFD has been
lost. The wiring may be incorrect, the MFD setup may not match the
wiring or the sensor may have an error.
Lightning Ahead
The Lightning Ahead option has been checked on the Lightning
Setup page. Displayed when a Lightning Ahead condition exists.
Lightning Heading Source Failed
Heading data is no longer available from the WX-500. Strike data
may still be valid. Will only appear if the WX-500 is used as the
heading source.
Lightning Heading Source OK
Heading data has been restored.
Stuck mic-PLEASE CHECK
Check your COM transmitters for indication of a stuck mike.
Lightning Antenna Location Changed
There may be an inconsistency between the antenna location
jumper setting and the software configuration. This message should
only appear during installation.
Lightning Position Source Failed
(TWX-670
only)
The position reporting source (GPS or FMS) connected to the
TWX-670 has encountered a fatal fault.
Lightning Position Source OK
(TWX-670 only)
The position reporting source (GPS or FMS) connected to the
TWX-670 has returned to normal operation.
Noise Present
(TWX-670 only)
The TWX-670 has detected excessive noise in the system.
Accuracy and efficiency of the lightning sensor may be
negatively affected.
Stuck MK
(TWX-670 only)
Microphone PTT switch is stuck open. Lightning strikes will
not be displayed until the problem is fixed.
No Position Data
(TWX-670 only)
The position reporting source (GPS or FMS) connected to the
TWX-670 is not sending position data.
Table 19: Lightning Sensor Messages (Continued)
Message
Meaning
Summary of Contents for 700-00004 Series
Page 2: ......
Page 4: ...EX5000 Installation Manual P N 600 00073 Rev 24 ii THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 10: ...EX5000 Installation Manual P N 600 00073 Rev 24 viii This page intentionally blank ...
Page 40: ...EX5000 Installation Manual P N 600 00073 Rev 24 30 Figure 6 EX5000 Landscape Front View ...
Page 92: ...EX5000 Installation Manual P N 600 00073 Rev 24 82 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 98: ...EX5000 Installation Manual P N 600 00073 Rev 24 88 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...EX5000 Installation Manual P N 600 00073 Rev 24 94 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 115: ...EX5000 Installation Manual P N 600 00073 Rev 24 105 Appendix J Wiring Diagram GPS FMS ...
Page 117: ...EX5000 Installation Manual P N 600 00073 Rev 24 107 Appendix L Wiring Diagram Traffic Sensors ...
Page 118: ...EX5000 Installation Manual P N 600 00073 Rev 24 108 Appendix M Wiring Diagram TAWS ...
Page 119: ...EX5000 Installation Manual P N 600 00073 Rev 24 109 Appendix N Wiring Diagram Radar Sensor ...
Page 120: ...EX5000 Installation Manual P N 600 00073 Rev 24 110 Appendix O Wiring Diagram Engine Sensors ...
Page 126: ...EX5000 Installation Manual P N 600 00073 Rev 24 116 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 130: ...EX5000 Installation Manual P N 600 00073 Rev 24 120 This page intentionally left blank ...
Page 131: ......