AVG-UHMS44
Invoke embedded EDID data for all inputs
Operation: Press “EDID” (hold for 3 seconds to enter in EDID setting status),
“ALL”+“O“ENTER”.
Example: Set the EDID data of all input ports to the second type of EDID data:
Press
(hold for three seconds)
or
to switch to the
2nd EDID data
.
Note:
If the conversion is successful, indicators of the pressed buttons will blink
green for three times at normal speed; if the conversion failed, they will blink for
three times quickly.
5.1.3. Inquiry
Check status:
Press and hold the button “ENTER” for 3 seconds, it will enter into system inquiry
menu. Use Left and Right direction button to navigate checking the previous/next
items.
Function Items
Example
Description
Check the
connection status of
inputs
Y means the corresponding
port is connected with input
device, N means not.
Check the
connection status of
outputs
Y means the corresponding
port is connected with output
device, N means not.
Correspondence
between inputs and
outputs
Shows the correspondence
between the 4 inputs and 4
outputs.
Check if the input is
with HDCP
Y means the input signal is
with HDCP, N means not.
Check if the output
is with HDCP
Y means the output signal is
with HDCP, N means not.
Check the output
resolution
Use the
UP
and
DOWN
direction button to check all
the 4 output resolutions.
Output check:
Press any output button to check its corresponding input.
Example: Check which one is the corresponding input for output 2. (Presume
Output 2 corresponds to Input 1.)
Operation: Press Output 2 button, LCD screen display “AV: 1->2 IR: 1->2”, and
indicators of input 1 and output 2 turn on and last for 3 seconds. Then output 2
corresponds to input 1.