background image

AVG-UDATP4 

 

4. System Connection 

4.1. System Applications 

Reliable performance for control and transmission makes the AVG-UDATP4 ideal in 
residential installations, signal monitoring, large screen displays, conference 
systems, television broadcast, education, banking and security institutions etc. 

4.2. Usage Precautions 

1.  System should be installed in a clean environment with temperature and humidity 

maintained to within equipment specifications. 

2.  All of the power switches, plugs, sockets and power cords should be insulated 

and safe. 

3.  All devices should be connected before power is turned on. 

 

4.3. Connection Diagram 

 

 

Note: Pictures shown in this manual are for reference only 

 

Summary of Contents for AVG-UDATP4

Page 1: ...res Compliant with HDMI 1 4 3D Transmit 4K x 2K signal up to 40m and 1080p signal up to 60m Supports PoC Supports IR control and cascade control Supports RS232 control and cascade control Real time display of working status via LED indicators Supports EDID configuration 5 types in total Supports cascading via HDMI OUT IR Loop and RS232 Loop ...

Page 2: ...operational instruction only and not to be used for maintenance The functions described in this version are current as at March 2015 Any changes of functions and operational parameters will be updated in future manual versions Please refer to your dealer for the latest product details Version 1 0 1 3 15 ...

Page 3: ...sed to extreme hot or cold temperatures 3 This unit will generate heat during operation please ensure that you allow adequate ventilation to ensure reliable operation 4 Please disconnect the unit from mains power if it will be left unused for a long time 5 Please DO NOT try to open the casing of the equipment DO NOT attempt to repair the unit Opening the unit will void the warranty There are high ...

Page 4: ...n Procedure 4 4 Cascade Connection 4 5 Cascade AV Signal 4 5 1 Cascade Control Signal 4 5 2 Twisted Pair Cable Connection 4 6 System Operations 5 IR Control 5 1 Control far end device from local 5 1 1 Control far end device from remote 5 1 2 RS232 Control 5 2 Installation Removal of RS232 Control Software 5 2 1 Basic Settings 5 2 2 Control far end device from local 5 2 3 Control far end device fro...

Page 5: ...o 60m If required use the HDMI local output to cascade the HDMI signal up to 4 times with additional AVG UDATP4 The AVG UDATP4 is also capable of bi directional IR transmission EDID management and PoC The AVG HD402PR HDBaseT receivers are recommended to utilize the full functionality of the HDBaseT outputs of this device 1 2 Features Compliant with HDMI 1 4 3D Transmit 4K x 2K signals up to 40m an...

Page 6: ...d for IR signal cascade 1 x RS232 cable 3 pin captive connector to DB9 1 x RS232 cable connect 2 3 pin captive connectors for cascading 4 x Plastic cushions 1 x Power Cord 1 x Power Adapter DC 24V 1 x User manual Note Please confirm if the product and the accessories are all included if not please contact your dealer ...

Page 7: ...l is without HDCP LINK Indicates linking status of the four HDBT sockets corresponding to the four HDBT sockets separately illuminates green when the corresponding HDBT socket is connected to AVG HD402PR successfully turns off when there is no AVG HD402PR connected to the corresponding socket HDCP HDCP compliance indicator corresponds with the receivers connected to the four HDBT ports illuminates...

Page 8: ...ssign ID for the AVG UDATP4 to identify every unit the value may vary from 0 F After assigning ID restart th eAVG UDATP4 for stable performance RS232 IN connect with control device through 3 pin captive cable LOOP cascade RS232 control signal to another splitter by connecting to its RS232 IN port Note Please set the communication protocol parameters correctly and refer to RS232 commands referring ...

Page 9: ...roadcast education banking and security institutions etc 4 2 Usage Precautions 1 System should be installed in a clean environment with temperature and humidity maintained to within equipment specifications 2 All of the power switches plugs sockets and power cords should be insulated and safe 3 All devices should be connected before power is turned on 4 3 Connection Diagram Note Pictures shown in ...

Page 10: ...directionally between AVG UDATP4 and AVG HD402PR s The IR signal is 5volt If you want to cascade the IR signal among several AVG UDATP4 units connect the IR LOOP socket of one of them and the IR IN socket of the next until all the AVG UDATP4 s have been connected Step6 Connect a DC 24V power adapter to the power port of the AVG UDATP4 the AVG HD402PR is able to be powered by the AVG UDATP4 using t...

Page 11: ...h RS232 Loop Connect the RS232 LOOP socket of the first AVG UDATP4 and the RS232 IN socket of the next until all the AVG UDATP4 units have been connected Sending RS232 commands will control all cascaded AVG UDATP4 simaltaneously Note To identify the AVG UDATP4 in cascading please set a unique ID for each unit when the cascade connection is done 4 6 Twisted Pair Cable Connection The twisted pair us...

Page 12: ... orange white 2 green 2 orange 3 orange white 3 green white 4 blue 4 blue 5 blue white 5 blue white 6 orange 6 green 7 brown white 7 brown white 8 brown 8 brown 1st 4 5 1st 4 5 Ground Ground 2nd 3 6 2nd 1 2 Ground Ground 3rd 1 2 3rd 3 6 Group Group 4th 7 8 4th 7 8 Group Group ...

Page 13: ...e following functions 1 Control a far end output device from local matrix location 2 Control a local input output device remotely 3 Control the AVG UDATP4 locally or remotely 5 1 1 Control a far end device from local unit Control the AVG UDATP4 or far end display device from local through corresponding IR remote ...

Page 14: ...y via corresponding IR remote As RS232 can be transmitted bi directionally between the AVG UDATP4 and the AVG HD402PR it is able to control a third party RS232 device locally or control the AVG UDATP4 from a remote location When controlling a third party RS232 device the baud rate of this device should be 9600 ...

Page 15: ...oval Delete all the control software files in corresponding file path 5 2 2 Basic Settings Firstly connect the AVG UDATP4 with an input device and an output device Then connect it with a computer which is installed with RS232 control software Double click the software icon to run this software Here we take the software CommWatch exe as example The icon is shown as below ...

Page 16: ...of the AVG UDATP4 is 01 and the device to be controlled is connected to HDBT port 2 then send the command 1B1 as 0121B1 Note To control AVG UDATP4 via RS232 port the communication protocol parameters should be configured in the right manner Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none 5 2 3 Control a far end device locally Connect the RS232 ports of the AVG UDATP4 and AVG HD402PR See Figur...

Page 17: ...4 Control a far end device from remote location Connect the RS232 ports of the AVG UDATP4 and AVG HD402PR See Figure Below then it is able to control the AVG UDATP4 or local display remotely by sending RS232 commands ...

Page 18: ...ange EDID data with reference to the following table Switcher Status EDID information 0000 default pass through auto process 0001 1080P 2D 0010 1080P 3D 0011 720P 2D 0100 720P 3D 0101 Optional DVI 1920x1080 Note EDID data is subject to change in further firmware versions Please refer to the details of further updated firmware ...

Page 19: ...to 7 1 Sample rates 32 kHz 44 1 kHz 48 kHz 88 2 kHz 96 kHz 176 4 kHz and 192 kHz Power Supply DC 24V HDBT 60m 196feet with HDMI video RS232 IR control PoC supports AVG HD402PR Control RS232 IR Full function pass though 5V IR RS232 port ID selectable for cascading Baud Rate 9600 Dimensions 220 x 148 x 44mm half rack wide Raw Materials Aluminum chassis Installation Standard Rack size provide removab...

Page 20: ...AVG UDATP4 7 Panel Drawing ...

Page 21: ...e via front panel buttons Front panel buttons are locked Send command Unlock or select unlock in GUI interface to unlock Cannot control the device via IR remote Flat Remote Battery Change battery Faulty Remote Send it to authorized dealer for repairing Beyond the effective range of the IR signal or not pointing at the IR receiver Adjust the distance and angle and point at the IR receiver The IR re...

Page 22: ...rs Type in correct RS232 communication parameters Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Broken RS232 port Send it to authorized dealer for checking Static becomes stronger when connecting the video connectors Poor grounding Check the grounding and make sure it is connected well Cannot control the device by RS232 IR remote front panel buttons The device has a previous fault Send it t...

Reviews: