20
ZM605 Indicator User Instructions
Operating Instructions
3.2.3 Using the Accumulation function
In the accumulator application the following softkeys are displayed and have the
functions described. Following that are in depth instructions for using them.
CHAN
key (
F1
)
Press this key to use the key pad and key in the desired
accumulator channel number (7 characters max).
ID
key (
F3
)
Press this key and key in the desired ID number (7 digits max).
SETPT
key (
F5
)
Press this key to set the setpoint or output values.
key
A brief key press, or triggering input #3, accumulates and
transmits data out serial port #1 (See sample below).
Chan. #
1
Trans #
2
Gross
52 lb
Tare
25 lb
Net
27 lb
Press and hold the
key to print the Total Format shown
below (if enabled in the supervisor menu):
Chan. #
1
Trans #
2
Gross Total
1077 lb
Tare Total
50 lb
Net Total
1027 lb
CHAN key (F1)
1.
Press this key and the alphanumeric entry screen appears.
2.
Key in the Channel number and press the
ENTER
key.
If the active unit of measure is lb-oz then tare weights must be entered in the oz
equivalent. To enter 2 lb 4.5 oz you would need to enter 36.5 oz (2 lb = 32 oz plus the
4.5)
Esc
Clear
.
# / ' %
7 Characters Max
Enter Channel
Remember to press the
Num Lock
key to enable the numeric keys.