ZM605 Indicator User Instructions
19
3.2 Accumulation weighing application
Using Entered Tare
To perform a net weighment using entered tare, the following steps describe a typical
operation:
1.
With no weight on the scale, if the display does not read
0
press
ZERO
…
0
is displayed and the
center-of-zer
o annunciator lights.
2.
Key in the tare value of the container or box that will be used to hold the
material that requires a net weight value, and press
TARE
…
Tare weight is displayed as a negative value and the
NET
weight is
display and the PT annunciator lights.
3.
Place the container or box and material to be weighed on the scale …
Net weight of material is displayed.
4.
If repeated weighments use the same tared item, you do not need to establish
a new tare value as described in step
5.
To remove the tare weight from the scale, enter
0
, then press
TARE
…
The tare is cleared and the scale is in gross weigh mode.
Using Preset Tare
Preset tares are entered in a password protected menu. Refer to details described in
the
. There are 10 tare values stored in memory. To
perform a net weighment using one of the preset tares, follow these steps:
1.
With no weight on the scale, if the display does not read
0
press
ZERO
…
0
is displayed and the
center-of-zero
annunciator lights.
2.
Press
TARE
…
EntEr
is displayed.
3.
Key in the desired preset tare number and press
ZERO
…
Tare weight is displayed as a negative value and the net weight is
displayed and the PT annunciator lights.
4.
Place container or box and material to be weighed on the scale …
Net weight of material is displayed.
Step
can be done prior to step
Press and hold
TARE
for 3 seconds and the display will show
cLEArEd
and the Tare
weight is cleared.
When the item is removed from the scale the Tare is cleared automatically if Auto
Tare Clear is enabled. To remove the tare weight manually, select a preset tare that
has a value of 0 for the tare or press and hold
TARE
for three seconds.