18
ZM605 Indicator User Instructions
Operating Instructions
Entered tare
When enabled key in a tare weight and press
TARE
to set.
Preset tare
When enabled press
TARE
and then enter a stored Preset Tare
number (1 - 10) and press
ZERO
to set.
Auto Tare Clear
If auto tare clear is enabled, after a weighment, when the weight falls into the gross zero
band, tare is cleared to zero.
The three types of tare are explained below.
Using Pushbutton Tare
To perform a net weighment using pushbutton tare, power up the unit and follow these
steps:
1.
With no weight on the scale, if the display does not read
0
press
ZERO
…
0
is displayed and the
center-of-zero
annunciator lights.
2.
Place item to be tared on the scale …
Weight is displayed.
3.
Press
TARE
…
0
is displayed and the
NET
weight is displayed.
4.
Place material to be weighed into or on the tared item on the scale …
Net weight of material is displayed.
5.
Repeatedly press
SELECT
to view the gross, tare, and net values.
6.
If repeated weighments use the same tared item, you do not need to establish
a new tare value as described in step
and
.
Pushbutton and Entered Tares can be enabled simultaneously.
Definition: Gross zero band - this is a configured value that defines a window around
gross zero. This is used in several ways in different applications.
Pressing
TARE
will perform the tare function but if you continue to press and hold
TARE
for 3 seconds the display will show
cLEArEd
and the Tare weight is cleared.
If gross weight is not at 0, press the
ZERO
key; then press the
TARE
key to clear the
tare value.