12
WI-125 SST Indicator Service Manual
If you forget your personal
code number, see
Sidestep-
ping Security Code Entry
section of this manual.
LCD version:
OFF
- Backlight does not
appear in Security or User
manual. (See
User's Manual)
ON
- Backlight maybe enabled
or disabled in User Menu. (See
User's Manual)
Auto
- Light in room is sensed
driving the backlight brighter in
dark rooms and turning off in
bright rooms. Backlight may be
enabled or disabled in User
menu. (See
User's Manual)
followed by the heavier ones. See
Entering Cutoff Values Through the
Front Panel
in the
User's Manual
. Setting to INGRED
allows entry of actual weight vs. having to make each
ingredient add on to the last ingredient
Latched— Selecting "yes" means that once a cutoff output is turned
off, it is to stay off until control is halted and then started
again. Further, once all cutoffs are off, the control is
automatically halted. Selecting "no" disables this behavior.
LATCHED
is offered only if
CONTROL
is enabled under
OPTIONS
and the total number of cutoffs is not zero.
Default = yes.
Setup, Scale, Options, Control, Tare, ID, Cutoffs-
Hour
(requires optional circuitry)
With this option you can choose to have the clock disabled (OFF) or
the mode of clock you want. You can choose the 12 hour clock
display or the 24 hour clock display. If the clock is disabled, HOUR
will not appear in the User's menu or in the
SECURITY
section of
this menu. (See the
User's Manual
) DAY will not appear in the
OPTIONS or SECURITY section of this menu.
Setup, Scale, Options, Control, Tare, ID, Cutoffs, Hour-
Day
(requires optional circuitry)
This option lets you choose to disable the calendar (OFF) or choose
the mode of calendar display you want. You can choose to display
the days (
dd
), months (
mm
), and year (
yy
) as
mm dd yy
, or
dd mm
yy
, or
yy mm dd
. If DAY is disabled, DAY will not appear in the
User's menu or in the
SECURITY
section of this menu. (See the
User's Manual
)
Setup, Scale, Options, Control, Tare, ID, Cutoffs, Hour, Day-
Acc
Choose to turn the accumulator ON or OFF.
Setup, Scale, Options, Control, Tare, ID, Cutoffs, Hour, Day, Acc-
Count
Choose to turn the Count ON or OFF. Count is the number of times
you have added to the accumulator.
Setup, Scale, Options, Control, Tare, ID, Cutoffs, Hour, Day, Acc, Count-
Light
For LCD version see note at left. Not applicable for LED version.
Setup, Scale, Options, Security-
Code No.
This option lets you change the configuration access code number
to a personalized security code number.
Summary of Contents for WI-125 SST
Page 1: ...WI 125 SST Indicator Service Manual LED version LCD version...
Page 2: ...2 WI 125 SST Indicator Service Manual...
Page 8: ...8 WI 125 SST Indicator Service Manual Figure 2 Configuration Menu...
Page 9: ...9 WI 125 SST Indicator Service Manual...
Page 36: ...36 WI 125 SST Indicator Service Manual...
Page 48: ...48 WI 125SST INDICATOR LED VERSION 115 230VAC SYSTEM BLOCK DIAGRAM...
Page 50: ...50 WI 125SST INDICATOR LED VERSION 115 230VAC KEYPAD OPTIONAL P C BOARDS...