11
WI-125 SST Indicator Service Manual
WI-125 LED Input/Outputs
TB4-6
+Signal
TB4-5
-Signal
TB4-4
+Sense
TB4-3
-Sense
TB4-2
+Exc.
TB4-1
-Exc.
TB8-5
DSR/CTS
TB8-4
DTR
TB8-3
Receive
TB8-2
Transmit
TB8-1
Ground
TB13-1
TB13-2
Zero
TB13-3
Tare
TB13-4
Ground
TB15-1
Cutoff 0
TB15-2
Cutoff 1
TB15-3
Cutoff2
TB15-4
Cutoff 3
TB15-5
Cutoff 4
TB15-6
Cutoff 5
TB15-7
Cutoff 6
TB15-8
Cutoff 7
TB15-9
Catch Diodes
TB15-10 Ground
TB15-11 +12 V
TB19-1
Voltage out
TB19-2
Current out
TB19-3
Current Rtn
TB19-4
Voltage Rtn3
Weigh Bar input
RS-232 output
Remote button
input
Cutoff output
(option card)
Analog output
(option card)
Control should be OFF when
using the RCU with start and
stop buttons.
Setup, Scale, Units, Capacity, Division, Zero, Stability,
A.Z.T., Update-
5, 1, 2
Choose the rate at which your display updates information, 1, 2, or 5
times per second. Five is the default value.
Setup, Scale, Units, Capacity, Division, Zero, Stability, A.Z.T., Update-
Average
This option allows you to choose the number of display update
period(s) over which the data are internally averaged prior to being
displayed. Any number between 1 and 10 may be entered. Five is
the default value.
Setup, Scale, Options-
Control
(Only on LED model)
Choosing ON allows you to "Start" the cutoff outputs from the front
panel. OFF disables this function. If cutoff control is disabled,
CONTROL will not appear in the SECURITY section of this menu or
in the Operations menu. Note that for CONTROL to appear in the
Operations Menu, the number of outputs selected under CUTOFFS
in the OPTIONS section of this menu must be a nonzero value.
Setup, Scale, Options, Control, Tare-
Button, Digital
Button - Choosing
ON
enables the pushbutton tare. Choosing
OFF
disables the pushbutton tare.
Digital -
Select the number of tare registers you want by keying in
a number. You can choose 0 through 9 tare registers.
If pushbutton tare is disabled and 0 tare registers are selected,
TARE
will not appear in the User's menu or in the
SECURITY
section of this menu. (See the
User's Manual
)
Setup, Scale, Options, Control, Tare-
ID
Choosing
ON
enables the ID number.
OFF
disables the ID number.
If ID is disabled,
ID
will not appear in User's menu or the
SECURITY
section of this menu. (See the
User's Manual
)
Setup, Scale, Options, Control, Tare, ID-
Cutoffs
(Only on LED model)
Total—
This option lets you choose the number of cutoffs you
want by keying in a number. If you choose 0 (zero) cutoffs,
CUTOFFS
will not appear in the
SECURITY
section of
this menu or in the Operations Menu. Also, in order for
CONTROL
to appear in the Operations Menu, a nonzero
number must be entered.
Ingred.— This option lets you choose the number of cutoffs you
wish to be “ingredient cutoffs” by keying in a number. If
you pick 0,
INGRED.
will not appear in the menu and the
cutoffs you have will be “setpoint cutoffs.” Cutoffs occur
according to weight. The lightest cutoffs occur first,
Summary of Contents for WI-125 SST
Page 1: ...WI 125 SST Indicator Service Manual LED version LCD version...
Page 2: ...2 WI 125 SST Indicator Service Manual...
Page 8: ...8 WI 125 SST Indicator Service Manual Figure 2 Configuration Menu...
Page 9: ...9 WI 125 SST Indicator Service Manual...
Page 36: ...36 WI 125 SST Indicator Service Manual...
Page 48: ...48 WI 125SST INDICATOR LED VERSION 115 230VAC SYSTEM BLOCK DIAGRAM...
Page 50: ...50 WI 125SST INDICATOR LED VERSION 115 230VAC KEYPAD OPTIONAL P C BOARDS...