Make sure the corner of the frames are fully and rigidly supported. If neces-
sary, use metal shims to ensure a good, level support.

Once the modules are properly installed, use the connector bolts, bevel
washers, and nuts to firmly attach each module together. Refer to Figure 8.

Loosen all check bolts - 4 per module

Remove the nuts from the hold down bolts; lower the bolts; then, replace the
nuts on the bolts, so they remain on the holding block on the frame.

Adjust the check bolts to a maximum of 3/16" clearance. Refer to Figure 3.

Install the optional bulkheads on each end of the scale.

If the bulkheads are from Weigh-Tronix, use (4) 3/4 - 10 x 2 1/2" bolts, bevel
washers, and nuts supplied by Weigh-Tronix. Refer to Figure 4.

If other than Weigh-Tronix bulkheads are used, ensure the proper clearance
between the scale platform and the bulkhead. Weigh-Tronix will not be
responsible for error caused by other bulkheads.

Once the bulkheads are properly installed, prepare the ramps at each end of
the scale. The ramps must be straight and level, for a minimum of 10 feet at
each end of the scale.

The ground rod must be installed as close as possible to the scale module
at the opposite end and same side as the junction box. Connect the ground
rod to the scale module frame using the supplied ground strap. Refer to
Figure 5. One ground rod should be installed for each end of a scale plus
one ground rod for each junction between modules.

Use the interconnecting cables to connect the modules together and to
connect the scale to the indicator. Leave the protective cover on the unused
connector. Apply nonconductive grease inside the removed protective caps
and if needed, apply nonconductive silicone grease on the cable before
connecting it to the box. Refer to Figure 9 for 2 module installations and
Figure 10 for 3 module installations.

Figure 9

Dual module wiring

Summary of Contents for BridgePort

Page 1: ...profile self contained portable scale suited for a wide variety of applications It is designed and manufactured for simplified temporary installation and relocation when necessary The basic units are...

Page 2: ...6 below the frost line To speed the installation of the scale ensure the proper installation of the piers before receiving the scale For the dimension information refer to the installation drawing Th...

Page 3: ...ock on the frame Adjust the check bolts to a maximum of 3 16 clearance Refer to Figure 3 Figure 3 Checkbolts Install the optional bulkheads on each end of the scale If the bulkheads are from Weigh Tro...

Page 4: ...d level for a minimum of 10 feet at each end of the scale The ground rods must be installed as close as possible to the scale module at each end and same side as the junction box Connect the ground ro...

Page 5: ...ll the T gap covers optional at each end of the scale to cover the gap between the edge of the scale deck and the bulkhead The scale is now ready for testing calibration and inspection as required Fig...

Page 6: ...n Position each module end to end Make sure the junction boxes remain on the same side of the scale To ensure the proper positioning of the second and third module if appli cable the units must be as...

Page 7: ...ulkhead Weigh Tronix will not be responsible for error caused by other bulkheads Once the bulkheads are properly installed prepare the ramps at each end of the scale The ramps must be straight and lev...

Page 8: ...box connectors Remove the tie down bolts and store them in a safe place for future use Install the hold down bolts to secure the scale weigh bridge to the frame To prevent movement of the scale platf...

Page 9: ...gh bar 15 std cable 271 73 0046 Weigh bar 50 std cable 271 73 0053 Weigh bar 15 S S sheathed cable 27173 0061 Weigh bar 50 S S sheathed cable 27173 0079 50 home run std cable 1 7 pin male connector 47...

Page 10: ...ction box cover to access the potentiometers 2 To capture the value of internal zero for your particular indicator refer to your indicator s Service Manual 3 Use test weights equal to 20 25 of full ca...

Page 11: ...A Weigh Tronix 1000 Armstrong Dr Fairmont MN 56031 USA Telephone 507 238 4461 Facsimile 507 238 4195 e mail industrial weigh tronix com www weigh tronix com Weigh Tronix Canada ULC 217 Brunswick Blvd...

Reviews: