34
Replacing the Ejector Rods
Disassembly
1.
Unplug the unit.
2.
Open the front door.
3.
Loosen the screw holding the scale plate for access to the black ejector slide, move
the scale plate up and tighten the screw.
4.
Remove the defective Eject Rod together with the black ejector slide.
Assembly
1.
Insert the bottom of the ejector rod into the hole in the eject block.
2.
Insert the top of the ejector rod into the hole and channel on the ejector slide.
3.
Repeat steps 1 and 2 for the second ejector rod.
4.
Loosen the screw and recover the scale plate.
5.
Tighten the screw.
Scale Plate
Ejector Rod
Slide
Ejector Rod
Entrance
of
Fastener
in
Ejector Block
Summary of Contents for ST9500