33
4
O
PERATION
4.1 A
CTIVATION
AND
SHUT
-
DOWN
ALS
380
The machine can also be automatically initial-
ised after switch-on by using the INIT function:
➔
In the standard menu, press the NEXT or PRIOR
key until INIT [26] is displayed on the operator pan-
el.
➔
Call the INIT function by pressing the ENTER key.
➔
Press and hold the FEED key.
– The message AUTO appears on the operator panel.
– The machine slowly starts up and dispenses a label.
➔
Release the FEED key once a label gap has passed
the photoelectric sensor at the dispenser head.
– If the initialisation was successful, "ON" appears on
the operator panel.
Manually initialise the material
If automatic initialisation is not possible, it does
not generally mean there is a malfunction. Man-
ual initialisation is often required if:
– the proper label stop sensor is not installed.
– transparent labels are used.
– labels with only a slight difference of trans-
parency between label and backing material
are used.
– perforated or otherwise blocked out labels
are used [27].
Only by qualified calibration technicians:
➔
Calling up the extended menu.
➔
Input the label distance using the LPIT
function
➔
Adjust the photoelectric sensor using the
CONT function.
➔
Refer to chapter
Operation
-
Settings in the
extended menu
.
[26] INIT display on the operator panel
[27]
A
Label distance
B
Photoelectric sensor
C
Labels with block outs (perforations)
A
B
C
C