Page|61
www.avenview.com
After finish the alignment, user can use [2x2] for complete image position fine tune. If user
executes [3x3] alignment again after [9x5] alignment, [9x5] grid position will be reset and only
keep [3x3] grid point information.
In ideal condition, all grids in edge blending area between two adjacent projectors should be
aligned together.
After the above processes, if the grid pattern in edge blending area still can’t stack together,
user can reduce overlapped grids to change the control point positions in adjacent projectors
and get more accurate geometry alignment result.
[EdgePro Windows Software] PC tool can provide 17x17 grid point adjustment with quicker
geometry alignment.
After finish geometry alignment, all grids should be matched together.