Page|41
www.avenview.com
✓
Under [Gwarp] menu, there are 10 UserMap. Each UserMap stores user geometry alignment
setting from Windows PC tool through USB or Ethernet. Once user selects UserMap setting,
then other geometry alignment will be reset and replaced with UserMap setting.
✓
UserMap only stores geometry alignment setting. This setting can be combined with other
functions to achieve edge blending or other purposes.
✓
If user doesn’t store any Windows setting to UserMap, when user clicks any UserMap menu or
select one UserMap without storing any Windows data, user may not see any image on the
screen. Under this condition, please press [2x2] geometry alignment hotkey on remote
controller to see OSD menu on the screen and execute further operations.
✓
[Fine tune]
If the system is installed based on Windows geometry data which is stocked in UserMap, user still
can execute small position modification through [Finetune] menu. This 4 corners position
adjustment range is +-50 pixels for each corner. This function is important for after service and
while changing lamp to return the image to original position.
8.3.7
[Gwarp]