Figures: View varies according to the series.
Ejector ECD-LV design
Description
Max. tightening
torques
1
Operation and display element
2
Valve “Blow-off”
1)
0.75 Nm
3
Manual override valve “Blow-off”
4
Vacuum connection G3/8"
10 Nm
5
Flow control screw for blow-off volume flow
6
Optionally integrated power blow-off module for
maximum blow-off volume flow (SMPi)
7
Silencer
8
Electrical connection plug M12 5-pin
hand-tight
9
Valve “suction”
2)
0.75 Nm
10
Manual override valve “Suction”
11
Compressed air connection G1/4"
10 Nm
12
Ejector mounting
6 Nm
13
Mounting screw for silencer
1 Nm
1)
Valve “Blow-off”:
All ejector variants NC function (with NO pilot valve)
2)
Valve “Suction”:
Ejector variant NO: NC pilot valve
Ejector variant NC: NO pilot valve
Pneumatic circuit diagrams
Ejector ECD-IV design
Description
Max. tightening
torques
1
Process status display
“Suction”/“Blow-off”/Vacuum value
2
Control elements
3
“Blow-off” flow control screw
4
G1/8" vacuum connection (identified as 2*)
4 Nm
5
Electrical connection M12
hand-tight
6
Control
7
Mounting hole
2 Nm
8
G1/8" compressed air connection (identified as 1*)
4 Nm
9
Silencer cover
0.5 Nm
10
Exhaust air outlet (identified as 3*)
11
Name plate incl. production date: <yy>W<ww>
(yy =year of production, ww= week of production>
*Identification number on the ejector, see figure.
In pos. 4 and pos. 8 only push-in fittings with cylindrical G-thread may be used.
1
1
2
11
4
3
6
8
9
7
11
10
5
11
12
13
8
9
10
6
7
2
1
3
4
5
2
ECD-IV...NO...
ECD-IV...NC...
3
Summary of Contents for ECD-IV
Page 30: ......