Press the filter button to activate the water filtration. The green indicator light will
turn on when the filtration system is activated.
Note:
- If massage function is on, the filtration can’t be activated.
Press the heating button to activate water heating and filtering system at the
same time. The green indicator light of filter and red indicator light of heating will
turn on at same time
The pump does not stop heating until the current water temperature reaches the
set temperature; and the heating system will restart after the current water tem-
perature drops 2°C below the set temperature automatically.
Maximum heating temperature: 40°C (104°F)
Important :
After 150 cumulative hours of filtration operations, an audible alarm will
sound and the LCD display will show the characters CHG, followed by FIL,
to remind you to change or clean the filter. You can hold the filtering button
5 seconds to turn off the buzzing. The filtering system will turn off, you can
press the button to active the filtering system again.
Note :
- With the heating system staring, the filtration system will start working together.
- After turning off the heating system, the filtration system will still work.
- If the massage function is active, the filtration and heating functions can not be activated.
4.3. Pool cover and security (Optional)
After each use, the control panel must be locked and the pool must be coated with its
top cover and it must be attached to the base protector with the safety buckles.
Each safety buckles has a lock system ; closed buckle, the latch in up position locks
the buckle, the latch in down position unlocks the buckle.
The top cover keeps the heat from the water and secures the pool.
5.1. Water maintenance
WARNING : A bad pool water quality can harm your health.
CAUTION: Please use chemicals properly. Quality problems caused by overuse
and improper use do not apply to our warranty.
Depending on the frequency and conditions of use:
- The filter cartridge should be regularly cleaned (150 hours max.).
- The filter cartridge should be replaced every 1 to 2 month.
- The pool water should be changed every 15 to 30 days.
Use a water test kit to control the parameters of the water before using the spa, or at
least once a week.
Use disinfection products for the spa. The treatment products should be used with
caution and it is imperative to refer to their instructions.
Damage resulting from improper use of treatment products is not covered
by warranty (overdose, shock treatment, ...).
1. Water balance
The water balance (pH) must be maintain between 7 and 7.4.
2. Water Sanitation
To sanitize the pool water, we suggest using an active oxygen-based
treatment or bromine placed in a floating dispenser. (Dispenser sold separately).
5. MAINTENANCE
5.2. Cleaning and replacing filter cartridge
Dirty filter cartridge may contaminate the pool water and cause damage to the heating
function.
1.
Unscrew the filter case by turning it counter-clockwise. Take out the filter cartridge
from the case.
2.
Rinse off the filter cartridge with a garden hose. If the filter cartridge remains dirty
and discoloured, the filter cartridge should be replaced.
3.
Put back the cleaned filter cartridge into his case and screw it to the pool.
Disinfection
Water Sanitation:
To sanitize the pool water, we suggest using an active oxygen-based treatment or bro-
mine placed in a floating dispenser. (Dispenser sold separately)
If water is heavily polluted you should not use pool.
Clean pool with with specialist UV lighting equipment.
Seek professional advice and guidance before doing this.
Attention:
Detergent residues and dissolved solids from bathing suits and chemicals may build
up on the spa walls, Use soap and water to clean the walls and rinse thoroughly with a
garden hose using a direct powerful waterspray