background image

 

User’s Manual

 

 

Pool Pump with Variable Rotation Speed

 

63908–63910

 

 
 

 

 
 
 
 
 

 

Illustration similar, may vary depending on model

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Read and follow the operating instructions and safety information before using for the first time.

 

 

Technical changes reserved!

 

Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further 
developments.

 

 

Updating the documentation

 

If you have suggestions for improvement or have found any irregularities, please contact us.

 

 

Summary of Contents for 63908

Page 1: ...erating instructions and safety information before using for the first time Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...ly If you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler...

Page 3: ...rol Three dials for quick speed control and up and down buttons for fine speed adjustment Low water protection Automatically shuts off when the pump detects a lack of water in the supply line Start up after water supply The pump recognizes whether there is still water after it has been switched off due to lack of water and can then be put into normal operation after water supply Power fail memory ...

Page 4: ...urn to the last menu 75 During operation short press this button to operate at 75 rate In the interface of the operation or shutdown state long press this key to switch the display content 50 During operation short press this button to operate at 50 frequency Press to finalize function codes or parameters Up arrow key During operation a short press of this button will increase the frequency by 1 I...

Page 5: ...ly return to the operation or shutdown menu 10 s later and the data changes will not be saved Parameter table Functional code Functional description Default value Parameter description F00 Model selection 60 The default value is 60 Hz F01 On off state 0 The fault condition is cleared a subsequent on off state and power failure are saved F02 Time to determine lack of water 90 In seconds F03 Time in...

Page 6: ...water 420 Limit of lack of water F32 Limit of 100 lack of water 720 Limit of lack of water F33 Class and power 1500 Standard power 1 5 kW F34 Fixed end code 23205 The fixed end code cannot be changed Note A factory error may differ from what is specified in the specifications which is a normal phenom enon Error codes Error code Error type Possible cause Solution E0 Control board EEPROM error EEPRO...

Page 7: ... P51 Protection against overvoltage of the busbar Input power overvoltage Fault in measuring circuit Check if input voltage is too high P60 IPM module low temperature protection Low ambient temperature Temperature too low components and parts cannot be put into oper ation normally P61 IMP module overheating pro tection Insufficient heat dissipation and protection of the module Incorrect installati...

Page 8: ...er it has been filled with water Check whether there are any foreign objects at the water inlet and outlet Change the order of the two UV phases in the case of counter clockwise operation Frequency report P61 Fan damaged Check whether the fan is dam aged or contact a specialist Message P49 or P0 after switching on and starting up the water pump Check that motor rotates counter clockwise Check if U...

Page 9: ...Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the protection of the environmen...

Reviews: